Mitsubishi Electric 800 Series Instruction Manual page 353

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

(M) Monitor display and monitor output signal
Increment
Monitor item
and unit
Second PID set
0.1%
point
Second PID
0.1%
measured value
Second PID
0.1%
deviation
Second PID
0.1%
measured value 2
Second PID
manipulated
0.1%
variable
Dancer main speed
0.01 Hz
setting
Control circuit
1°C
temperature

Indication with a minus sign is not possible via RS-485 or MODBUS RTU communication.

When using the item as the main monitor data on the LCD operation panel (FR-LU08) or the parameter unit (FR-PU07), use Pr.774 to Pr.776 or
the monitor function of the FR-LU08 or the FR-PU07 for setting.

The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from
0.

The actual operation time does not increase if the cumulative running time before power OFF is less than an hour.

When using the parameter unit (FR-PU07), "kW" is displayed.

Differs according to capacities. (FR-A860-01080 or lower / FR-A860-01440 or higher)

The setting is available only for standard models.

When the output current is less than the specified current level (5% of the inverter rated current), the output current is monitored as 0 A.
Therefore, the monitored value of an output current and output power may be displayed as "0" when using a much smaller-capacity motor
compared to the inverter or in other instances that cause the output current to fall below the specified value.

Can be changed to the pulse display after the electronic gear using Pr.430 Pulse monitor selection. (Refer to
 Available when the plug-in option or control terminal option is connected.
 Input terminal monitor details ("1" denotes terminal ON, "0" denotes terminal OFF, and "―" denotes undetermined value.)
b15
 Output terminal monitor details ("1" denotes terminal ON, "0" denotes terminal OFF, and "―" denotes undetermined value.)
b15
 Option input terminal monitor 1 details (FR-A8AX input terminal status, "1" denotes terminal ON and "0" denotes terminal OFF.) ―― All are OFF
when the option is not connected.
b15
X15
X14
X13
X12
 Option input terminal monitor 2 details (FR-A8AX input terminal status. "1" denotes terminal ON, "0" denotes terminal OFF, "―" denotes
undetermined value.) ―― All are OFF when the option is not connected.
b15
 Option output terminal monitor details (FR-A8AY/A8AR output terminal status. "1" denotes terminal ON, "0" denotes terminal OFF, and "―" denotes
undetermined value.)―― All are OFF when the option is not connected.
b15
 The increment is 1 when Pr.37 = "1 to 9998" or when Pr.144 = "2 to 12, or 102 to 112". (Refer to
 The monitored values are retained even if an inverter fault occurs. Resetting will clear the retained values.
 Parameter setting is not available for setting the item as the main monitor data on the LCD operation panel (FR-LU08) or the parameter unit (FR-
PU07). Use the monitor function of the FR-LU08 or the FR-PU07 for setting.
 Negative values are not displayed on the operation panel. The values "-1 to -32767" are displayed as "65535 to 32769" on the operation panel.
 Setting of Pr.1018 Monitor with sign selection is required. Also, it will be displayed without a minus sign on the operation panel. Confirm the
rotation direction with the [FWD] or [REV] indicator.
352
PARAMETERS
Pr. setting
92
H5C
93
H5D
94
H5E
95
H5F
96
H60
97
H61
98
H62
STP
CS
RES
(STOP)
X11
X10
X9
RA3
Negative
MODBUS
RS-485
indication
RTU
40292
40293
40294
40295
40296
40297
40298
MRS
JOG
RH
RM
ABC2
ABC1
X8
X7
X6
X5
RA2
RA1
Y6
Y5
Description
(-)

Displays the set point, measured
value, and deviation under second
PID control. (Refer to
Displays PID measured value even if
PID control operating conditions are
not satisfied while the second PID
control is enabled (Pr.753 ≠ "0").
(Refer to
page
497)
Displays the second PID control
manipulated amount.
(Refer to
page
497)
Displays the main speed setting
under step control
Displays the temperature of the
control circuit board.
(Refer to
page
390.)
Without minus sign: 0 to 100°C
With minus sign: -20 to 100°C
page
227.)
RL
RT
AU
STR
FU
OL
IPF
SU
X4
X3
X2
X1
Y4
Y3
Y2
Y1
page
345.)
page
497)
b0
STF
b0
RUN
b0
X0
b0
DY
b0
Y0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents