(E) Environment setting parameters
Automatic parameter setting (Pr.999)
• Select which parameters to automatically set from the table below, and set them in Pr.999. Multiple parameter settings are
changed automatically. Refer to
Pr.999
Setting
1
Sets the standard monitor indicator setting of PID control.
2
Automatically sets the monitor indicator for PID control.
Automatically sets the communication parameters for the GOT connection with a PU
10
connector ("Controller Type" in GOT: FREQROL 500/700/800, SENSORLESS SERVO)
Automatically sets the communication parameters for the GOT connection with RS-485
11
terminals ("Controller Type" in GOT: FREQROL 500/700/800, SENSORLESS SERVO)
Automatically sets the communication parameters for the GOT connection with a PU
12
connector ("Controller Type" in GOT: FREQROL 800 (Automatic Negotiation))
Automatically sets the communication parameters for the GOT connection with RS-485
13
terminals ("Controller Type" in GOT: FREQROL 800 (Automatic Negotiation))
20
50 Hz rated frequency
21
60 Hz rated frequency
NOTE
• If the automatic setting is performed with Pr.999 or the automatic parameter setting mode, the settings including the changed
parameter settings (changed from the initial setting) will be automatically changed. Before performing the automatic setting,
confirm that changing the parameters will not cause any problem.
PID monitor indicator setting (Pr.999 = "1 or 2")
Pr.
759
PID unit selection
1142
Second PID unit selection
774
Operation panel monitor selection 1
775
Operation panel monitor selection 2
776
Operation panel monitor selection 3
934
PID display bias coefficient
935
PID display gain coefficient
1136
Second PID display bias coefficient
1138
Second PID display gain coefficient
3-step monitor setting
Direct setting
Dedicated parameter list function

Enabled when the FR-PU07-01 is used.
256
PARAMETERS
page 257
for the list of parameters that are changed automatically.
Description
Sets the related parameters of the rated frequency according to
the power supply frequency
Name
Initial value
9999
9999
9999
9999
9999
9999
9999
9999
9999
Pr.999="1"
Pr.999="2"
9999
4
9999
4
9999
52
9999
53
9999
54
9999
0
9999
100
9999
0
9999
100
Disabled
Enabled

Disabled
Enabled

Disabled
Enabled

Refer to page
501
347
501