Pr.
Pr.
group
Terminal 1 added compensation
243
T041
─
amount (terminal 4)
244
H100
─
Cooling fan operation selection
245
G203
Rated slip
246
G204
Slip compensation time constant
Constant-power range slip
247
G205
compensation selection
248
A006
─
Self power management selection
Earth (ground) fault detection at
249
H101
─
start
250
G106
─
Stop selection
Output phase loss protection
251
H200
─
selection
252
T050
Override bias
253
T051
Override gain
254
A007
─
Main circuit power OFF waiting time 1 to 3600 s, 9999
255
E700
Life alarm status display
Inrush current limit circuit life
256
E701
display
257
E702
Control circuit capacitor life display (0 to 100%)
258
E703
Main circuit capacitor life display
Main circuit capacitor life
259
E704
measuring
PWM frequency automatic
─
260
E602
switchover
261
A730
Power failure stop selection
Subtracted frequency at
262
A731
deceleration start
263
A732
Subtraction starting frequency
264
A733
Power-failure deceleration time 1
265
A734
Power-failure deceleration time 2
Power failure deceleration time
266
A735
switchover frequency
─
267
T001
Terminal 4 input selection
268
M022
─
Monitor decimal digits selection
269
E023
─
Parameter for manufacturer setting. Do not set.
Stop-on contact/load torque high-
─
270
A200
speed frequency control selection
High-speed setting maximum
271
A201
current
Middle-speed setting minimum
272
A202
current
273
A203
Current averaging range
Current averaging filter time
274
A204
constant
Stop-on contact excitation current
275
A205
low-speed multiplying factor
PWM carrier frequency at stop-on
276
A206
contact
Name
Setting range
0 to 100%
0, 1, 101 to 105
0 to 50%, 9999
0.01 to 10 s
0, 9999
0 to 2
0, 1
0 to 100 s,
1000 to 1100 s, 8888,
9999
0, 1
0 to 200%
0 to 200%
(0 to 15)
(0 to 100%)
(0 to 100%)
0, 1
0, 1
0 to 2, 11, 12, 21, 22
0 to 20 Hz
0 to 590 Hz, 9999
0 to 3600 s
0 to 3600 s, 9999
0 to 590 Hz
0 to 2
0, 1, 9999
0 to 3, 11, 13
0 to 400%
0 to 400%
0 to 590 Hz, 9999
1 to 4000
0 to 300%, 9999
0 to 9, 9999
0 to 4, 9999
Parameter list (by parameter number)
Minimum
setting
Initial value
increments
0.1%
75%
1
1
0.01%
9999
0.01 s
0.5 s
1
9999
1
0
1
0
0.1 s
9999
1
1
0.1%
50%
0.1%
150%
1 s
600 s
1
0
1%
100%
1%
100%
1%
100%
1
0
1
1
1
0
0.01 Hz
3 Hz
0.01 Hz
60 Hz
0.1 s
5 s
0.1 s
9999
0.01 Hz
60 Hz
1
0
1
9999
1
0
0.1%
50%
0.1%
100%
0.01 Hz
9999
1
16
0.1%
9999
1
9999
PARAMETERS
Parameter List
Refer
to
page
Pr.
398
List
324
618
618
618
454
325
607
326
398
398
454
262
262
262
262
262
261
526
526
526
526
526
526
393
347
463,
466
5
466
466
466
466
463
463
103