Table 10: Rack Requirements and Specifications for WLC100 Wireless LAN Controllers
Rack Requirement
Rack type
Mounting bracket hole spacing
Rack size and strength
Rack connection to building
structure
Related
Documentation

Cabinet Requirements for WLC100 Wireless LAN Controllers

Table 11: Cabinet Requirements and Specifications for WLC100 Wireless LAN Controllers
Cabinet
Requirement
Guidelines
Cabinet size
You can mount the controller in a cabinet that contains a 19-in. rack as defined in Cabinets, Racks,
Panels, and Associated Equipment (document number EIA-310–D) published by the Electronics Industry
Association (
Cabinet clearance
The outer edges of the rack-mount tray extend the width of the chassis to 19 in. (48.2 cm).
The minimum total clearance inside the cabinet must be 30 in. (76.2 cm) between the inside of the
front door and the inside of the rear door.
22
Guidelines
Use a two-post rack or a four-post rack. You can mount WLC100 controllers on any 19-in.
two-post or four-post rack that provides bracket holes or hole patterns spaced at 1 U (1.75 in.
or 4.45 cm) increments and that meets the size and strength requirements to support the
weight. A U is the standard rack unit defined in Cabinets, Racks, Panels, and Associated
Equipment (document number EIA-310–D) published by the Electronics Industry Association
http://www.eia.org
(
).
The holes in the mounting brackets are spaced at 1 U (1.75 in. or 4.45 cm), so that WLC100
controllers can be mounted in any rack that provides holes spaced at that distance.
Ensure that the rack complies with the size and strength standards of a 19-in. rack as
defined in Cabinets, Racks, Panels, and Associated Equipment (document number
EIA-310–D) published by the Electronics Industry Association (
Ensure that the rack rails are spaced widely enough to accommodate the external
dimensions of the WLC100 controllers chassis. The outer edges of the rack-mount tray
extend the width of the chassis to 19 in. (48.2 cm).
The rack must be strong enough to support the weight of WLC100 controllers.
Ensure that the spacing of rails and adjacent racks allows for the required clearance around
WLC100 controllers and rack.
Secure the rack to the building structure.
If earthquakes are a possibility in your geographical area, secure the rack to the floor.
Secure the rack to the ceiling brackets as well as wall or floor brackets for maximum
stability.
Cabinet Requirements for WLC100 Wireless LAN Controllers on page 22
Chassis Physical Specifications of WLC100 Wireless LAN Controllers on page 4
Mounting WLC100 Wireless LAN Controllers on a Rack or Cabinet on page 30
You can mount WLC100 controllers on two posts of a 19-in. rack or cabinet.
Table 11 on page 22
provides the cabinet requirements and specifications for WLC100
controllers.