7 Technical data

7.1 Medium
Working medium:
Max. permissible viscos-
ity:
7.2 Temperature
Media temperature:
Ambient temperature:
7.3 Pressure
Operating pressure:
Leakage rate:
www.gemu-group.com
Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and
chemical properties of the body and seal material.
600 mm²/s (cSt)
Other versions for lower/higher temperatures and higher viscosities on request.
-10 — 180 °C
0 bis 60 °C*
* je nach Ausführung und/oder Betriebsparametern (siehe Kapitel Einschalt- und Lebensdauer)
DN
Actuator size 0
(code 0A)
15
15
20
10
25
6
32
-
40
-
50
-
All pressures are gauge pressures.
For max. operating pressures the pressure / temperature correlation must be observed.
Higher operating pressures on request
Open/Close valve
Seat seal
Standard
Metal
DIN EN 12266-1
EPDM, FKM, PTFE
DIN EN 12266-1
Actuator size 1 (code
1A),
Open/Close valve (code
A0)
40
32
23
15
9
6
Test procedure
P12
P12
9 / 55
7 Technical data
Actuator size 1 (code
1A),
control valve (code S0)
25
15
10
6.5
4
1
Leakage rate
Test medium
F
A
GEMÜ 533 eSyStep
OPEN / CLOSE (Code AE)
Air
Air