7 Technical data
7.7 Electrical data
Supply voltage Uv:
Rating:
Operation:
Reverse battery protec-
tion:
7.7.1 Digital input signals
Inputs:
Input voltage:
Logic level "1":
Logic level "0":
Input current:
7.7.2 Digital output signals
Outputs:
Type of contact:
Switching voltage:
Switching current:
Short-circuit proof:
7.7.3 Communication
Interface:
Function:
Transmission rate:
Frame type in Operate:
Min. cycle time:
Vendor-ID:
Device-ID:
Product-ID:
ISDU support:
SIO operation:
IO-Link specification:
IODD files can be downloaded via https://ioddfinder.io-link.com/ or www.gemu-group.com.
GEMÜ 533 eSyStep
OPEN / CLOSE (Code AE)
24 V DC ± 10%
Actuator size 0 (code 0A)
Actuator size 1 (code 1A)
Stepper motor, self-locking
Yes
Function selectable via IO-Link (see table Overview of available functions – Input and output sig-
nals)
24 V DC
> 15.3 V DC
< 5.8 V DC
typically < 0.5 mA
Function selectable via IO-Link (see table Overview of available functions – Input and output sig-
nals)
Push-Pull
Power supply Uv
≤ 140 mA
Yes
IO-Link
Parameterization/process data
38400 baud
2.5 (eSyStep ON/OFF, code AE, A5, A6)
2.3 ms (eSyStep ON/OFF, code AE, A5, A6)
401
1906701 (eSyStep ON/OFF, code AE, A5, A6)
eSyStep On/Off (code AE, A5, A6)
Yes
Yes
V1.1
20 W
60 W
12 / 55
www.gemu-group.com