Technical Data - GEM eSyStep 543 Operating Instructions Manual

Motorized angle seat globe valve
Table of Contents

Advertisement

7 Technical data

7 Technical data
7.1 Medium
Working medium:
Max. permissible viscos-
ity:
7.2 Temperature
Media temperature:
Ambient temperature:
7.3 Pressure
Operating pressure:
Leakage rate:
GEMÜ 543 eSyStep
OPEN / CLOSE (Code AE)
Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and
chemical properties of the body and seal material.
600 mm²/s
Other versions for lower / higher temperatures and higher viscosities on request.
-10 — 180 °C
0 — 60 °C
depending on version and/or operating parameters (see chapter Duty cycle and service life)
DN
Actuator version
0A
6
-
8
10
-
15
15
20
10
25
6
32
-
40
-
50
-
Pressures in bar
All pressures are gauge pressures.
For max. operating pressures the pressure / temperature correlation must be observed.
Higher operating pressures on request
Open/Close valve
Seat seal
Standard
Metal
DIN EN 12266-1
EPDM, FKM, PTFE
DIN EN 12266-1
Actuator version
0E
25
25
25
25
-
-
-
-
-
Test procedure
P12
P12
10 / 68
Actuator version
1A
Open/Close
Control valve
valve
(code S0)
(code A0)
-
-
-
-
-
-
25
25
25
15
23
10
15
6.5
9
4
6
1
Leakage rate
Test medium
F
Air
A
Air
www.gemu-group.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

543 esystep

Table of Contents