INTRODUCTION

Congratulations on your purchase of a Brivis Cooling system. For you to achieve the performance and efficiency
expected from your new cooler, please ensure the installer is a qualified trades person, that the installer has
commissioned the unit before you commence operating, and you take the time to read the contents of this manual.
In some Australian States it is mandatory that your cooler installation is issued with a certificate of compliance
to guarantee the installation workmanship� Please check with your installer or the local plumbing authority or
association� The Brivis cooler is covered by the product warranty as outlined in this manual�

HOW DOES YOUR EVAPORATIVE COOLING WORK?

The amount of cooling available from any type of cooling system is dependent on the outside weather conditions�
Your evaporative cooler works best on hot, dry days. It is essential to provide the required amount of ventilation (for
your evaporative cooling system to function properly) by opening windows/doors whenever the cooler is operating�
Air is drawn in through the filter pads resulting in 100% fresh cool air entering the home. The movement of this
cooled air through your home will draw the heat out of the house, so be sure that doors or windows are open to
expel this heat to outside.
Whenever possible start the cooler early to prevent the build up of heat within the house, and on sultry or humid
days your cooler may work better with the fan ONLY running and the pump turned OFF. Stale air, cigarette smoke
and fumes can be quickly cleared and replaced with fresh air by turning the fan to manual mode�

BEFORE OPERATING YOUR EVAPORATIVE COOLER

Make sure enough window and/or door area is open for the unit to work correctly� The following table gives a guide
to the amount of open area required for each model in m
Brivis Models
Promina
Advance
Contour
Series
Series
L36
P36
P46
L46
P56
L56
P66
L66
P76
L76
Average ventilation
Door = 1.6m²
area
provided
by
various
openings
when fully opened�
You can also choose to have these openings only halfway open. However, the opening will only
provide half the amount of ventilation shown and additional ventilation openings would be required.
NOTE
Brivis

EVAPORATIVE COOLER OPERATION

Advance
AD Series
Series
Plus
F36D
AD56BAL
F56D
F46DS
AD56DBAL
AD66/BAL
F66DS
AD66D/BAL
F76D
F86DS
AD86D
, and also gives suggestions on how to provide this.
2
Number of average
size windows & doors
(suggestions only)
One door and a hinged window
Three sliding windows or one
door & two hinged windows
Four sliding windows or one
door and four hinged windows
Five sliding windows or one
door and five hinged windows
AD86
Six sliding windows or one door
and six hinged windows
7
Highest
Fan
Setting
1�9 m
2
2�3 m
2
2�8 m
2
3�1 m
2
3�4 m
2
Hinged Window = 0.3m²
Sliding Window = 0.7m²
Evap AC OM
Lowest
Fan
Setting
1�1 m
2
1�4 m
2
1�7 m
2
1�9 m
2
2�1 m
2