COOLER SERVICE & MAINTENANCE
To ensure that your Brivis cooler continues to operate at peak efficiency, it should be serviced at two year intervals
by an authorised person trained in the service of Brivis coolers - please contact our National Care Centre, for
authorised Brivis Service Technicians� Refer to the back of this manual for contact details�
This service of the cooler unit will include all maintenance and adjustments required to the following components
to ensure your cooler runs at its peak efficiency:
Trough
Electronic Controls e�g� Sensors
Please note that to maintain your warranty, the above servicing needs to be conducted by an
authorised person trained in the service of Brivis Coolers. Please contact our Brivis Service
Department for an authorised Brivis Service Technician.
IMPORTANT
Service maintenance is not covered under warranty and is a chargeable service. All coolers must
have safe and reasonable access and be installed in compliance with the installation instructions
supplied with the unit. Some installations may require two service personnel to attend, in
NOTE
accordance with Health & Safety requirements.

SAVE A SERVICE CALL

Service calls can often be avoided! If you feel your cooler is not operating property, please check these possible
causes first:
General Troubleshooting
Check the water supply to the unit is turned ON�
Ensure the pump is operating and visually check the pads for even water distribution�
Check that the number of doors and windows open is sufficient within the targeted cooling area. Too many or
not enough doors and windows opened in the targeted area could result in inadequate ventilation� This could
result in poor cooling performance�
Check that the fan operates and air is coming out from the duct outlet�
Check that the filter pads are not damaged and/or the material hasn't deteriorated.
If external weather conditions are excessively humid, the cooler may not perform at its optimal cooling level.
If the fan will not start.
Check if the power is ON�
Check if the Wall Control is turned ON, and set the comfort level that requires the Cooler fan to operate.
Check that the fan is not in Time Delay Mode caused by: pre-programmed times
for the ServoSeal damper (Brivis Contour Series only) and motorised drain to
open, the Cooler's tank to fill with water, or a pre-wet of the filter pads.
Check the fuse in the meter box.
The unit will not turn on
Check the circuit breaker has not been tripped - if so reset it� Reset the Cooler at the power supply�
The unit is blowing warm air
Check the water supply tap is turned on at the unit� Check the pump has been selected on the wall control
An error message is appearing on the Brivis Networker
Refer to the section on "Coded Messages" on page 13 and follow the checks� Check the power point is
plugged in and turned on to the Cooler�
The Brivis Networker display is blank
Check there is power to the power point with another appliance� Check the circuit breaker has not been tripped
- if so reset it�
Brivis
CARE & MAINTENANCE
Fan and Pump Assembly
19
Pads and Water Distribution
The usual time
delay can be up
to 8 Minutes.