PROGRAMMABLE CONTROL OPERATION

OPERATING YOUR PROGRAMMABLE WALL CONTROL

This Wall Control gives the choice of Automatic or Manual modes with the option of a time ON or OFF delay�

AUTOMATIC PRE-WET

When the cooler is turned on with both the fan and the pump, in either Auto or Manual mode, the cooler will start
a Pre-Wet stage to ensure the pads are thoroughly wet before the fan starts. This contributes to the effective
operation and performance of the cooler� The Pre-Wet time will vary depending on how long the cooler has been
OFF, and whether it needs to fill the tank prior to operation.

OPERATING MODES

The cooler has several operating modes, which are as follows:
1�
Auto mode
2�
Manual mode Fan and Pump
3�
Manual mode Fan only
4�
Manual mode Pump only�
Push the MODE key to cycle through the cooler's operating modes�
The wall control will remember previously established settings in Auto and Manual Modes.
NOTE

AUTO OPERATION

In AUTO mode the Programmable Wall Control automatically operates the cooler (fan speed and pump) to maintain
the selected 'comfort level'� The cooler may even turn OFF if the conditions meet the comfort level setting�

GETTING STARTED

Begin by pressing the On/Off key to turn the Cooler on. If the Auto light is illuminated, the system is set for
Automatic operation, otherwise:
Press the mode key to cycle through the Cooler's operating modes, until the Auto light is illuminated.
Push the UP and DOWN keys to select the comfort level you require. The lower the number, the cooler the
setting; the higher the number, the warmer the setting.

BENEFITS OF USING IN AUTO MODE IN PREFERENCE TO MANUAL MODE

Power and water consumption varies in relation to the chosen comfort level�
This comfort level cannot be as easily maintained in Manual mode�
In auto mode the unit operates only when it is required�
Enables a set comfort level to be maintained automatically as the outdoor/indoor temperature conditions change�
Allows you to pre-set the cooler to turn ON early and not let the house build up heat�
The outlet airflow noise is kept to a minimum, as the fan speed is only as fast as required to maintain the set
comfort level. This slower speed also results in more efficient saturation of the cooler filter pads, and a cooler
outlet air temperature�
Brivis
16
Evap AC OM