Machine Setting- Others Page

The Others Page allows you to change various settings that correspond to the control panel. The Language
setting will allow users to change available languages displayed on the control panel.
The Unit setting will allow you to change whether the units displayed by the control panel is in the metric or
imperial system. The EOF (end of file) Alarm setting will enable or disable an audible notification when jobs are
complete. The Air Delay setting allows you to specify the delay in seconds of the SmartAIR air-assist after the
point of laser firing.
Language: ENGLISH (others dependent on Firmware)
Unit: METRIC/ INCH
EOF Alarm: YES/ NO
Air Delay: 1-100 seconds
Tip
Depending on the material you are working with, your laser settings, and the desired results, please
experiment with the air delay to achieve your desired results.
Relevant Buttons
F1 (Back)
F4 (Save)
 /  Directional
 /  Directional
Start / Stop
Auto Focus
 /  Manual Focus Buttons
Others Page
Back to previous page
Save your current settings
Scroll through the menu selections
Adjust the value for that selection
Back to Main Work Page
Initiate the auto focus function
Manually adjust the height of the work table (Z-axis)
99