Atms Reports - Avaya MCC1 Maintenance Procedures

Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

ATMS reports

The list testcalls command produces detailed and summary reports of measurements made by the ATMS.
Measurement reports contain data on trunk signal loss, noise, singing return loss, and echo return loss,
and are used to determine the quality of trunk lines. The system maintains a database with the results of
the last test for each trunk. System resets clear all transmission test data, and ATMS measurements are
not backed up by the MSS.
ATMS parameters are administered on the Trunk Group screen. These include thresholds for marginal
and unacceptable performance. On the screen display, measurements that exceed the marginal threshold
are highlighted. Measurements that are exceed the unacceptable level appear flashing, indicating
unusable trunks. Trunk groups can be administered to log errors and alarms, and to busy out the failed
trunk in response to such results.
The detailed report lists measurements for each trunk-group member. The summary reports lists trunk
groups as a whole. The measurements that are displayed depends on what type of test, if any, was last run
on the trunk, and the capabilities of the TTL on the switch at the far end of the trunk. See
on page 401
for a description of the test analog-testcall command. A blank line indicates that no test data
is available for that trunk or group.
The number of pages of each report is dependent upon the selection criteria and the number of outgoing
trunks in the system. About 10 measurements can be listed on a page on the administration terminal, or
about 50 measurements can be listed on a printer. By default, reports list every measurement. Filtering
can be used to limit the output. For example, the report can be set up to print only failed measurements.
The syntax of the command is as follows:
list testcalls detail | summary
[port UUCSSpp]
[grp group#] [to-grpgroup#]
[mem member#] [to-memember#]
[resultresultID> | not-resultresultID]
[count#] [print | schedule]
Input parameters
Input
detail
summary
grp #
to-grp
mem
Maintenance Procedures
December 2003
Description
Show each measurement made for each trunk.
Show totaled results of ATMS tests for trunk groups as a whole.
Show measurements for a specific trunk group. When used with to-
grp, this option specifies the starting trunk group in a range.
Show measurements for every trunk group from one up to the trunk-
group number entered. When used with grp, this is the ending trunk
group in a range.
When used with grp, show measurements for a specific trunk-group
member. When used with to-mem, this is starting trunk-group member
in a range.
Additional maintenance procedures
Automatic Transmission Measurement System
(1 of 2)
Test call results
403