Systems With Nonduplicated Spes - Avaya MCC1 Maintenance Procedures

Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

S8700 only

Systems with nonduplicated SPEs

1
Power down the control carrier.
2
Remove the suspected circuit pack.
3
Determine whether the backplane pins in the removed circuit pack's slot are bent.
4
If the backplane pins are bent:
a Straighten or replace the pins.
b Insert the same circuit pack.
If not, replace the circuit pack (reinsert the old one if a replacement is not available).
5
Turn the power back and allow the system to reboot. This may take up to 12 minutes. Log in at the
terminal.
6
Determine whether the packet-bus fault is still present. If not, you are finished.
If the problem is still present,
a
If the old circuit pack was reinserted in
b
If the circuit pack was replaced in
If Procedure 3 fails to identify the cause of the problem, go to Procedure 4.
High- and critical-reliability systems
1
To remove a PN's IPSI circuit pack, use set ipserver-interface Uc if necessary to make the
suspected circuit pack the standby. (Before executing an interchange, always check the status of
the standby IPSI's Tone-Clock circuit with status port-network.)
To remove a PN's Tone-Clock circuit pack, use set tone-clock if necessary to make the suspected
circuit pack the standby. (Before executing an interchange, always check the status of the standby
Tone-Clock with status port-network.)
2
Determine whether the backplane pins in the removed circuit pack's slot are bent.
3
If the pins are bent:
a Power down the carrier if it is not already.
b Straighten or replace the pins.
c
Insert the same circuit pack.
d Restore power to the carrier.
4
If the backplane pins are not bent, reinsert or replace the circuit pack.
5
Determine whether the packet-bus fault has been resolved. If so, you are finished.
If not, do the following:
a If the old circuit pack was reinserted in
Procedure 3 starting at
b If the circuit pack was replaced with a new one, proceed with
Maintenance Procedures
December 2003
Step
5, replace the circuit pack, and repeat Procedure 3.
Step
5, repeat Procedure 3 for the next SPE circuit pack.
Step
4, replace the circuit pack, and repeat
Step
2.
Packet and serial bus maintenance
Isolating and repairing packet-bus faults
Step
6.