Avaya MCC1 Maintenance Procedures page 387

Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

3
Enter add trunk n to add a new (test) trunk group. Then enter information for the following
fields:
Group Type
TAC
Trunk Type (in/out)
Port
Mode
Type
Figure 116, Trunk Group form, page 2,
Figure 116: Trunk Group form, page 2
GROUP MEMBER ASSIGNMENTS
4
Locate the tie trunk port terminal connections at the cross-connect field. Consult the appropriate
table above for either 110-type or 66-type hardware.
5
At the cross-connect field, disconnect outside trunk facilities from the analog tie trunk ports and
mark the disconnected wires for later when the tie trunk ports are placed back into normal
operation. The D impact tool (AT-8762) is required to perform this step.
6
Use jumper wires (DT 24M-Y/BL/R/G) and the D impact tool to connect wiring between the two
ports assigned in
Trunk circuit pack are ports 1 and 2, connect the wirings as shown below:
Maintenance Procedures
December 2003
tie
Use trunk access code obtained from dial
plan.
wink/wink
Assign two of the ports from the tie trunk.
simplex
type 5
on page 387 shows page 2 of the Trunk Group form.
TRUNK GROUP
Port
Name
1: B1901
2: B1902
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
15:
Step 4
at the cross-connect field. For example, if the two ports on the analog Tie
Additional maintenance procedures
Analog tie trunk back-to-back testing
Mode
Type
Answer Delay
simplex
type 5
simplex
type 5
Page
2 of
5
387