Avaya G350 Installing And Upgrading page 51

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Note:
The leftmost LINE analog telephone port on the G350 front panel forms a
Note:
mechanical analog relay with the TRUNK port next to it. See
can be configured to provide emergency transferred telephone service in the
case of a power outage or disconnection from an external media server.
Therefore, the analog telephone connected to this LINE port is usually installed
for this emergency purpose. Regular analog telephones on the network are
usually connected to other analog ports.
Figure 12: The MM711 media module
Figure 13: The MM714 media module
Figure 14: The MM716 media module
Note:
Analog line ports support the following maximum distances:
Note:
- For phone equipment with a ringer load above 3 REN (old mechanical ringers):
- Up to 10,000ft for 26 AWG wire
- Up to 16,000ft for 24 AWG wire
- Up to 20,000ft for 22 AWG wire
- For modern phone equipment with a ringer load below 0.1 REN (electronic
ringers):
- Up to 20,000ft for 26 AWG, 24AWG, and 22AWG wire
Step 1: Connecting data and voice devices