List Of Necessary Materials/Tools - Bard MULTI-TEC W18ABP Series Literature Assembly

Wall-mount air conditioner and heat pumps
Table of Contents

Advertisement

LIST OF NECESSARY MATERIALS/TOOLS

Additional hardware and miscellaneous supplies are needed for installation. These items are field supplied and must
be sourced before installation. This list also includes tools needed for installation.
List of Materials/Tools
Personal protective equipment/safety devices/anti-
static wrist straps
Supply and return grilles
Field-fabricated sleeves (if necessary)
Fasteners sufficient for mounting the units such as
5/16" diameter anchor/lag bolts
7/8" diameter washers
Fasteners appropriate for the shelter wall
construction to attach the controller to the wall
Commercial grade outdoor silicone sealant
Miscellaneous hand and power tools and jobsite or
shop materials
Lifting equipment with the necessary capacity and
rigging to safely move/install the systems
W
36
A
MODEL SERIES
CAPACITY
18 – 1½ Ton
24 – 2 Ton
30 – 2½ Ton
36 – 3 Ton
A – Right Hand
L – Left Hand
REVISION
P – PLC Logic Board
E – PLC with Electric Reheat Dehumidification
A – 230/208/60/1
B – 230/208/60/3
C – 460/60/3
D – 240/220/50/1
 Having "B" in this position in the
model number disables all economizer
function. Emergency vent will still
operate when "B" is in this position.
Manual 2100-713A
Page
6 of 44
MULTI-TEC W18-36A/LB Wall-Mount Unit Model Nomenclature
B
P
A
10
VOLTS & PHASE
E – 240/220/50/3
or 220/200/50/3
F – 415/380/50/3
Q – 575/60/3
KW
VENTILATION OPTIONS
B – Blank-off Plate 
5 or E – Economizer
Electrical supplies
- Various size circuit breakers for the shelter AC
breaker box (see Electrical Specification tables
on pages 16, 17 and 18)
- High-voltage wire of various gauges
(see tables on pages 16, 17 and 18)
- 16 gauge minimum, 14 gauge maximum power
wire to connect controller to shelter power source
- 5-wire, 18 gauge shielded cable for remote
temperature and humidity sensors (2-wire, 18
gauge shielded cable for temperature-only sensors)
- Communication wire: 2-wire, 18 gauge, shielded
with drain
- 18 gauge non-shielded wire for connecting
emergency off, emergency vent and/or generator,
if applicable, to controller
- CAT 6 Ethernet cable of field-determined length
(for remote communication, if applicable)
- 2 hole grounding lug (to be used with supplied
1/4" bolts and nuts for grounding controller box)
- Miscellaneous electrical supplies including rigid/
flexible conduit and fittings, 2" x 4" junction
boxes (one per temperature/humidity sensor),
wire connectors and supports
FIGURE 1
5
X
X
X
PLACEHOLDER
X for future use
COLOR OPTIONS
X – Beige (Standard)
1 – White
4 – Buckeye Gray
5 – Desert Brown
FILTER OPTIONS
X – 1" Throwaway (Standard)
W – 1" Washable
P – 2" Pleated (MERV 8)
X
E
CONTROL MODULES
E – Low Ambient Control
C – Low Ambient Control
and Crank Case Heater
COIL OPTIONS
X – Standard
1 – Phenolic Coated Evaporator
2 – Phenolic Coated Condenser
3 – Phenolic Coated Evaporator and
Condenser
4 – Coated Coils and Condenser Section
5 – Coated Coils, Inside and
Outside of Unit
8 – Dark Bronze
S – Stainless Steel
A – Aluminum
M – 2" Pleated (MERV 11)
N – 2" Pleated (MERV 13)