Verification Result Output; Output Of The Master Data Registered - Denso GT10B-SU User Manual

Bar code handy scanner
Table of Contents

Advertisement

8.1.3 Verification result output

(1) Report of match/mismatch status
You can select any of the following report types by using the bar-coded parameter menu or configuration software
(ScannerSetting). Selecting "Disable transmission" reports nothing.
Setting
1
Disable transmission.
2
Enable bar code data transmission.
3
Enable bar code data transmission.
4
Enable OK transmission.
(2) Beeper, indicator LED and vibrator
You can check whether the verification result is a match or mismatch, with the beeper, indicator LED and vibrator.
When the beeper, indicator LED and vibrator are enabled, they act as listed below.
If there is a match:
If there is a mismatch:
(3) Scan lock
The scan lock function locks the scanner on standby if the verification result is a mismatch. You can enable or disable this
function with the bar-coded parameter menu or configuration software (ScannerSetting).
Once the scanner is locked, it switches to standby regardless of the current trigger switch control selected. The scanner
remains on standby even if the trigger switch is pressed or a ready-to-scan command (R, READON or LON) is received.
Pressing the magic key or turning off the scanner releases the scan lock.

8.1.4 Output of the master data registered

Scanning the "Output master data" bar code given below lets the scanner output the verification section of master data
registered in the verification setup procedure.
If there is a match:
Beeper
Emits a short beep.
Emits a long beep.
Output master bar code
If there is a mismatch:
Disable transmission.
Disable transmission.
Enable NG transmission.
Enable NG transmission.
Indicator LED
"OK" vibrations
Lights in blue.
Operates.
Lights in red.
30
Vibrator
"NG" vibrations
--
--
Operates.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gt11b-suGt10b-lu

Table of Contents