Explicit Messages
Explicit
Read/
message
write
Action on
Write
Writes the action
Bus Idle
performed when
the bus enters
idle state.
Read
Reads the action
performed when
the bus enters
idle state.
Note
(1) The Instance ID specifies the Slice I/O Unit's unit number (1 to 63 decimal).
(2) Digital output 1 is supported only by the Positioning Unit. "Digital output 0" applies to both the digital
output on Counter Units and digital output 0 on Positioning Units.
(3) Range 1 is supported only by the Positioning Unit. "Range 0" applies to both the comparison range
on Counter Units and comparison range 0 on Positioning Units.
(4) The data structure is as follows:
If you want to write "LL = 7FFF FFFF, UL = 8000 0000" use the following: FFFF FF7F 0000 0080.
210
Function
Service
Class
code
0E hex
8E hex 01 to 40
0E hex
8E hex 01 to 40
Command
Instance
Attribute
ID
ID
ID
98 hex
*1
hex
98 hex
*1
hex
Appendix A
Response
Data size
1 byte
---
00 hex: Outputs
are cleared on
bus idle.
01 hex: Output
functionality is
maintained on
bus idle.
1 byte
---
00 hex: Outputs
are cleared on bus
idle.
01 hex: Output
functionality is
maintained on bus
idle.