Installation Of Remote Switch For Rn/Rp Gas Valve - Vermont Castings D232 Installation Instructions & Homeowner's Manual

Free-standing direct vented fireplaces
Table of Contents

Advertisement

When using copper or flex connector use only approved
fittings. Always provide a union when using back iron
pipe so that gas line can be easily disconnected for burner
or fan servicing. See Fig. 2. See gas specification for
pressure details and ratings.
The fireplace valve must not be subjected to any test
pressures exceeding 1/2 psi. Isolate or disconnect this or
any other gas appliance control from the gas line when
pressure testing.
DO NOT USE THIS FIREPLACE IF ANY
PART OF THIS FIREPLACE HAS BEEN
UNDER WATER. IMMEDIATELY CALL
A QUALIFIED SERVICE TECHNICIAN
TO INSPECT THE HEATER AND TO
REPLACE ANY PART CONTROL
WHICH HAS BEEN UNDER WATER.
INSTALLATION OF REMOTE
SWITCH FOR RN/RP GAS VALVE
Install on/off switch assembly on either the rear right or left
side of the Fireplace.
1. Remove the screw at the back of the cabinet top either
on the left or the right side of the fireplace.
2. Position switch assembly onto the back of the fireplace,
then fasten two screws as shown in Fig. 5.
3. Attach wiring under the clips on the rear casing (Fig. 5)
and install wiring through the rear opening of the
fireplace before connecting to the valve as shown in
Fig. 4.
THERMOPILE
ON/OFF SWITCH OR
MILLIVOLT THERMOSTAT
On/off switch
assembly
Clips
- 6 -
VALVE
Fig. 4
Screw
(through existing hole)
Screw
Wiring for milli-volt
gas valves
Fig. 5