1/2" Gas Supply
1/2" x 3/8" Reducer
3/8" Nipple
Fig. 4 Typical gas supply installation.
During any pressure testing of the gas line system,
when the test pressures are to exceed 1/2 psi (3.5 kpa)
the fireplace and its gas valve must not be connected
to that system.
At test pressures equal to or less than 1/2 psi, the gas
valve of the fireplace may be connected to the gas line,
but must be in the closed position.
Some municipalities have additional local codes, it is
always best to consult the local authority and the CSA-
B149.1 installation code in Canada.
FOR U.S.A Installations consult the current National
Fuel Gas Code, ANSI Z223.1
Always check for gas leaks with a mild soap
and water solution. Do not use an open
flame for leak testing.
Brass
Thermostat
Plug
Bulb
Gas Inlet
Thermocouple Inlet
Pilot Tube Entry
Pilot
Adjustment
Screw
Minimum Rate Screw
(Nonadjustable)
Fig. 5 On fireplaces equipped with the Eurosit 630 gas
valves, there are brass plugs in two of the holes. These
plugs are not to be removed. The gas inlet hole has a plastic
cap in it. Remove the plastic cap and connect your gas
supply line at this point.
The MN/MP valve control used on the
RHE25 does not include the thermostat
bullb as shown in Figure 5.
10000836
Vermont Castings, Majestic Products RHE Natural Vent Insert
3/8" x 3/8" Shut Off
Valve
3/8" Union
FP1278
Manifold Gas
Outlet
Brass Plug
Pressure
Regulator
Control Knob
Control Knob
it
HV118
Installation of Remote Switch
for RN/RP Gas Valves
1. Thread wire through gas inlet opening on the right
side of fireplace. Do not cut wire or insulation on
metal edges.
2. Slide switch assembly from the back, between
subframe and trim, then fasten the screw. (Fig. 6)
3. For left side installation reverse switch position in
bracket and repeat Step 2. (Fig. 7)
4. Connect wiring to gas valve (Fig. 8a & b) and switch.
Right Side Installation
Trim Right
Side
ON/OFF Switch
Assembly
Trim
Screw
ON/OFF Switch Assembly
Fig. 6 Slide switch assembly between subframe and trim.
ON/OFF
Switch
Fig. 7 For left side installation, reverse switch position in
bracket.
Valve
Thermopile
Fig. 8a ON/OFF switch or millivolt thermostat.
Left Side Installation
Trim Top
Trim Left
Side
Wiring from
Millivolt Gas
Trim
Valve
Screw
FP1253
Bracket Switch
FP1254
FP382a