Vermont Castings DVRT36 Homeowner's Installation & Operating Manual
Vermont Castings DVRT36 Homeowner's Installation & Operating Manual

Vermont Castings DVRT36 Homeowner's Installation & Operating Manual

Vermont indoor gas fireplace operating manual
Table of Contents

Advertisement

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED EX-
ACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR
LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or the
gas supplier.
WHAT TO DO IF YOU SMELL
GAS:
• Do not try to light any appliance.
• Do not touch any electric switch;
do not use any phone in your
building.
• Immediately call your gas
supplier from your neighbor's
phone. Follow the gas suppliers
instructions.
• If you cannot reach your gas
supplier call the fire department.
DO NOT STORE OR USE
GASOLINE OR OTHER FLAM-
MABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
Direct Vent
Models: DVRT36
Homeowner's Installation &
Vermont Castings, Majestic Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
DVRT39
DVRT43
Operating Manual
C E RT I F I E D
10002428 11/03 Rev. 5

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings DVRT36

  • Page 1 ANY OTHER APPLIANCE. Vermont Castings, Majestic Products INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER Direct Vent Models: DVRT36 Homeowner's Installation & Operating Manual 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.com...
  • Page 2: Table Of Contents

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE. Thank You and Congratulations on your purchase of a Vermont Castings, Majestic Products Fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important

    14. When the fireplace is not in use it is recommended that the gas valve be left in the “OFF” position. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of...
  • Page 4: Fireplace Dimensions

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 Fireplace Dimensions (Installed as Top Vent) Gas Line Access Electrical Access Fig. 2 Fireplace specifications and framing dimensions. Ref. DVRT36 36” (914mm) 37 ” (946mm) 34 ” (870mm) 21” (533mm) 32 ” (835mm) 20”...
  • Page 5 7 ” 10 ” 18” ” (1436mm) 40” (1016mm) 14 ” 36 ” 35” 25 ” 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Rough Opening Depth Q - Rough Opening Width Rough Opening Height 2" (51mm) DVRT39 (914mm) 39”...
  • Page 6: Clearance To Combustibles

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 Clearance to Combustibles Appliance Top ... 0” (0mm) Bottom ... 0” (0mm) Side ... 0” (0mm) Back ... 0” (0mm) Venting Concentric sections of DV Vent ... 1” (25mm) Non-concentric sections of DV Vent Sides and bottom ...
  • Page 7: Framing & Finishing

    If a Trim Kit is to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the appliance. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Model DVRT36RN DVRT36RP DVRT36EN...
  • Page 8: Gas Line Installation

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 Gas Line Installation When purging the gas lines, the front glass must be removed. The gas pipeline can be brought in through the side of the fireplace as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection.
  • Page 9: Eb-1 Electrical Box

    Electrical Box Inside Outside Fig. 9 EB-1 receptacle. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 This appliance may be fitted with a Honeywell ignition module. Installation of the remote on/off starter switch on electronic ignition units: 1. Thread the wiring through the holes on the side panels of the appliance.
  • Page 10: Optional Top Vent Application

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 Optional Top Vent Application The DVRT appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent configuration the appliance can be converted by following the steps below.
  • Page 11: General Venting

    24” (610mm) from the front of the termination hood. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 General Venting • Do not locate the termination hood where excessive snow or ice buildup may occur.
  • Page 12: General Venting Information -Termination Clearances

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 General Venting Information - Termination Location VENT TERMINATION CFM145a A = Clearance above grade, veranda, porch, deck, or balcony B = Clearance to window or door that may be opened C = Clearance to permanently closed window...
  • Page 13: General Information For Connecting Vent Pipes

    CSA-B149.1 installation code. USA Installations: The venting system must conform to local codes and/ or the current National Fuel Code ANSI Z223.1/NFPA 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Outside Corner Combustible 6" (152 mm) Noncombustible 2"...
  • Page 14: Twist-Lock Pipes

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 Twist-lock Pipes When using Vermont Castings, Majestic Products twist-lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the collars on the fireplace and the sliding joint of any telescopic vent section used in the system.
  • Page 15: Rear Wall Vent Installation

    3 sheet metal screws. Install the 7” (175mm) vent pipe to the appliance collar and secure with 3 sheet metal screws. If a 45° elbow is being 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Vent Opening — Combustible Wall (240mm) 10 "...
  • Page 16: Vertical Sidewall Application

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 Finished Wall These ends screwed These ends to appliance. should be even. Fig. 22 Flat to the wall installation. Vertical Sidewall Application It is very important the venting system maintain its balance between the combustion air intake and the...
  • Page 17: Vertical Sidewall Installation

    Total angular variation = 270° 1 + 2 + 3 + 4 = 270° Fig. 26 Maximum elbow usage. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Vertical Sidewall Installation 7’ (2134mm) Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location.
  • Page 18: Below Grade Installation

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 Step 2 Measure wall thickness and cut zero clearance sleeve parts to proper length (maximum 12” / 305mm). As- semble sleeve and attach to firestop with #8 sheet metal screws (supplied). Install firestop assembly.
  • Page 19: Vertical Through-The-Roof Application

    #8 x 1/2 sheet metal screws. For a recessed foundation wall, it is necessary to extend vent pipes out as far as the protruding wall face. (Fig. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Foundation Watertight Seal Around Pipe Fig.
  • Page 20: Vertical Through-The-Roof Installation

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 • Up to two (2) 45° elbows may be used within the horizontal run. For each 45° elbow used on the horizontal plane, the maximum horizontal length must be reduced by 18” (450mm).
  • Page 21: Gravity Ducting System

    10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Do not discharge directly into a wall or inside an enclosure. 3. Materials needed for the gravity ducting installation: •...
  • Page 22 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Sheet Metal Screws Fig. 40 Gravity vent locations. Gravity Duct Plug CFM180 10002428...
  • Page 23: Venting Components, Twist-Lock & Crimp End

    10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Twist Lock Venting Components 7TDVRVT - Through-the-Wall Rear Vent Termination Starter Kit - Model 7TDVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting Starter Kit - Model 7TDVSKS - Snorkel Kit Snorkel Termination - 7TDVSNORK 45˚...
  • Page 24 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Crimped End Venting Components 7DVRVT - Through-the-Wall Rear Vent Termination Starter Kit - Model 7DVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7DVSKV-A: Order 1/12 to 6/12 roof pitch...
  • Page 25: Operating Instructions

    7. To replace window frame assembly, reverse this procedure. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Operating Instructions Fig. 42 Window frame assembly removal. It is necessary to periodically clean the glass panel. It is normal for condensation to form on the inside of the glass during start-up.
  • Page 26: Installation Of Logs & Lava Rock

    Do not place any of this material on the burner housing assembly. NOTE: Glowing lava rock for DVRT36 is only allowed to be positioned at the front area (radiant portion) of the burner housing assembly.
  • Page 27: Flame & Temperature Adjustment

    NOTE: Glowing lava rock for DVRT43 is allowed to be positioned only at the front area (radiant portion) of the burner housing assembly. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 LG228 Fig. 45 DVRT43 logset and ember placement. Flame & Temperature Adjustment RN/ RP Models For units equipped with ‘HI/ LO’...
  • Page 28: Inspecting The Venting System

    Electronic Ignition Fig. 48 Correct pilot flame appearance. 5 Separate flames Glowing Lava Rock Fig. 49 Correct burner flame appearance for DVRT36. 5 Flame areas Glowing Lava Rock Fig. 50 Correct burner flame appearance for DVRT39. PSE Pilot Fig. 51 Correct burner flame appearance for DVRT43.
  • Page 29: Lighting And Operating Instructions

    2. Turn off all electric power to the fireplace if service is to be performed. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Lighting & Operating Instructions • If you cannot reach your gas supplier, call the Fire Department.
  • Page 30 Vermont Castings, Majestic Products DVRT36/ 39/ 43 For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury and loss of life.
  • Page 31: Instructions For Rf Comfort Control Valve

    Switch Fig. 52 Comfort control valve. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 7. If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting and the fan will be at the highest fixed speed. The transmitter will control the fan only.
  • Page 32 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Delay Time Mode The shutoff delay timer has a maximum of two (2) hours, and a minimum of zero (0) minutes. To change the timer level, press the timer key, then an arrow key.
  • Page 33: Auto Path Chart

    LED Count NOTE: Some keys are not active. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Auto Path Chart Service Action Replace valve Confirm stepper motor connection exists Confirm fan connection exists and works Confirm gas type; jumper in place...
  • Page 34: Comfort Valve System Control Sequence Of Operation With Transmitter

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 Comfort Valve System Control Sequence of Operation with Transmitter Local Path If manual switch is set to LOCAL, did main burner light and fan turn on? Turn pilotstat knob to PILOT to turn off main burner.
  • Page 35: Troubleshooting Guide

    Pilot Lights With Piezo Ignitor Pilot Stays Lit Pilot Lights Main Burner SYSTEM OK 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Remove the Window Frame Assembly before service work. CHECK • Supply Line Hooked Up • Shutoff Valve Open •...
  • Page 36 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Troubleshooting the Gas Control System Note: Before trouble shooting the gas control system, be sure external gas shut off is in the “ON” position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT.
  • Page 37 SYSTEM RUNS UNTIL ON/OFF SWITCH IS IN "OFF" POSITION TROUBLESHOOTING ENDS 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 CHECK: • LINE VOLTAGE (120VAC) • LOW VOLTAGE TRANSFORMER (19.5 minimum VAC) • ON/OFF SWITCH • WIRING CONNECTIONS UNPLUG IGNITION LEAD...
  • Page 38: Fuel Conversion Instructions

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 Fuel Conversion Instructions The conversion of this appliance from one gas to another must be carried out by an authorized service provider. 1. Disconnect power to unit and shut off the gas supply.
  • Page 39: Maintenance

    Do not use water or household cleaners on any brass components. Contact your local representative to arrange an annual service program. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Conversion Screw The burner and control system consists of: Pressure Regulator...
  • Page 40: Replacement Parts

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 DVRT43 DVRT39 DVRT36 Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications and prices, and to discontinue colors and products at any time, without notice. DVRT36/39/43 9a/b 10 a/b...
  • Page 41 Gas Valve - SIT 820 - LP 26a. Gas Valve - Honeywell - Natural 26b. Gas Valve - Honeywell - LP 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 (Items marked ‘*’ are not shown in the parts illustration.) DVRT36 10002427 57897 10001454...
  • Page 42 Vermont Castings, Majestic Products DVRT36/ 39/ 43 DVRT36/39/43 (continued) Ref. Description FK24 Fan Assembly w/Bracket (Optional) FK12 Fan Assembly (not shown) Electric Cord 6’ (Optional) (not shown) Fan Speed Control (Optional) (not shown) Fan Speed Control Knob (Optional) (not shown)
  • Page 43: Optional Accessories

    4. The power supply may be connected in 2 ways: 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Optional Accessories Method A: Route the 6’ (1.8m) lead fitted to the unit to a conveniently located wall socket.
  • Page 44: Remote Controls

    When fitting the bay window kits the original front frame/glass assembly must remain in place. The bay window kit is fitted over the existing front glass. Bay window kits are available for the DVRT36 and DVRT39 model fireplaces. Installation 1. Remove the existing louvre assembly bottom complete with the hinges.
  • Page 45: Decorative Frame Trim

    Contact your authorized distributor for details of the trim kits and ordering information for the trim kits applicable to this model appliance. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43 Bay Window Frame Ceramic Refractory...
  • Page 46: For Use In Mobile Homes: Model Dvrt36Mh

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 For Use in Mobile Homes: Model DVRT36RMH This appliance may be installed as an OEM installation in a manufactured home (US only), or a mobile home; it must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard Title 24 CFR Part 3280, or Standard for Installation in Mobile Homes CAN/ CSA Z240 MH.
  • Page 47 Fire up the unit, check for flame impingement on the logs, adjusting them if necessary. Check the manifold and supply pressures. NOTE: If further assistance is required, refer to ‘Troubleshooting’ and ‘Parts List’ in this manual. 10002428 Vermont Castings, Majestic Products DVRT36/ 39/ 43...
  • Page 48: Warranty

    Vermont Castings, Majestic Products DVRT36/ 39/ 43 PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
  • Page 49 Vermont Castings, Majestic Products DVRT36/ 39/ 43 10002428...
  • Page 50: Energuide

    Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) DVRT36RN 59.5 DVRT36EN 59.8 DVRT36EN 59.5 DVRT36EP 59.8 DVRT36RFN 59.5 DVRT36RFP 59.8 DVRT36RMH 59.5 DVRT39RN 65.4 DVRT39RP 66.8 DVRT39EN 65.4 DVRT39EP 66.8 DVRT43RN 63.7 DVRT43RP 63.7 DVRT43EN 63.7 DVRT43EP 63.7 Vermont Castings, Majestic Products 410 Admiral Blvd.

This manual is also suitable for:

Dvrt43Dvrt39

Table of Contents