Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner
A =
Combustible
A
6"(152mm)
Noncombustible
2"(50mm)
V
Balcony -
with no side wall
G
V
G =
Combustible&
Non-Combustible
12"(305mm)
Outside Corner
B =
Combustible
Noncombustible
V
B
Balcony -
with perpendicular side wall
H
V
Combustible &
Non-Combustible
H = 24"(610mm)
J = 20"(508mm)
- 8 -
Recessed Location
6"(152mm)
2"(50mm)
C = Maximum depth of 48"
D = Minimum width for back wall
J
E = Clearance from corner in
D
C
C
E
V
(1219mm) for recessed
location.
of a recessed location.
Combustible 38"(965mm)
Noncombustible 24"(610mm)
recessed location.
Combustible 6"(152mm)
Noncombustible 2"(50mm)