Installation For Gas Valve Kits; Supplemental Instructions; Spk-Nga/Spk-Lpa - Vermont Castings VWF18STN Installation And Operating Instructions Manual

Vented gas log set
Table of Contents

Advertisement

VWFST Series Vented Gas Log Set
SUPPLEMENTAL INSTRUCTIONS FOR SPK-
NGA/SPK-LPA
LG1050
Burner Fitting
Pipe Nipple
Figure 5 -
Connect Valve to Unit
(natural Gas only)
LG1050
SPK valve connection
LG1151
LP Air-Mixing
Injector
Figure 6 -
Connect Valve to Unit
LG1051
(LP only)
SPK lp valve connection
The Safety Pilot Kit attaches to the burner pan as shown above.
Use soapy water when checking all fittings for leaks.
8
Natural Gas
Injector
Reducer
Gas Control
Valve
Burner Fitting
Brass Nut
Gas Control
Valve

INSTALLATION FOR GAS VALVE KITS

LP sets must be installed with a SPK or
MVVKLP Kit which includes the air mixing
nut and vermiculite. The natural gas orifice
must be removed.
Adjust pilot flame to cover
thermocouple
SPK-NGA Kit Includes
Valve
Pilot (Configured for NG)
Pipe Nipple
Heat Shield
Knob Extenders
SPK-LPA Kit Includes
Valve
Pilot (Configured for LP)
Air Mixing Nut
Brass Nut
Heat Shield
Knob Extenders
27D8851