Vermont Castings DVRS3 Installation Instructions & Homeowner's Manual
Vermont Castings DVRS3 Installation Instructions & Homeowner's Manual

Vermont Castings DVRS3 Installation Instructions & Homeowner's Manual

Vermont castings rear vented direct vent installation instructions & home owner's manual
Table of Contents

Advertisement

Installation Instructions & Homeowner's Manual
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electric switch
* Do not use any phone in your building.
* Immediately call your gas supplier from
your neighbours phone. Follow the gas
suppliers instructions.
* If you cannot reach your gas supplier call the
fire department.
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
The Vermont Castings
Majestic Products Company
410 Admiral Blvd., Mississauga
Ontario, Canada L5T 2N1
www.majesticproducts.com / www.vermontcastings.com
- 1 -
Rear Vented
Direct Vent Models
DVRSL
DVRSR
FOR YOUR SAFETY
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPOURS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
* Installation and service must be performed
by a qualified installer, service agency or
your gas supplier.
DVRS3
10001293
11/01 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings DVRS3

  • Page 1: For Your Safety

    The Vermont Castings Majestic Products Company 410 Admiral Blvd., Mississauga Ontario, Canada L5T 2N1 - 1 - Rear Vented Direct Vent Models DVRS3 DVRSL DVRSR DO NOT STORE 10001293 11/01 Rev. 1...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Please read the Installation & Operating Instructions before using this appliance. Thank you and congratulations on your purchase of a Majestic fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Installation Instructions

    INSTALLATION AND OPERATING INSTRUCTIONS This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN /CGA- B149 (. 1 or .2) Installation codes for Gas Burning Appliances and Equipment. or for U.S.A Installations follow local codes and/or the current National Fuel Gas Code.
  • Page 4: Fireplace Dimensions

    MANTEL CHART Ref. Mantel Width Ref. Height from Top Louvre 10" (254 mm) 8" (203 mm) 6" (152 mm) 4" (101 mm) 2" ( 51 mm) FIREPLACE DIMENSIONS DVRS3 22" 559mm 1/2" 622mm 29" 737mm 1/2" 63mm 4"...
  • Page 5: Clearance To Combustibles

    Millivolt Hi/Lo 34,000 Millivolt Hi/Lo 34,000 Natural Gas Millivolt Hi/Lo 34,000 Millivolt Hi/Lo 34,000 DVRS3 / DVRSL / DVRSR CERTIFIED TO ANSI Z21.88-1998 / CSA 2.33 - M98 Vented Gas Fireplace Heaters LP (Propane) NATURAL 11" wc 4.5" wc 7" wc 13"...
  • Page 6: Gas Line Installation

    This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless an avail- able certified kit is used.
  • Page 7: General Venting Information

    GENERAL VENTING Your fireplace is approved to be vented either through the side wall, or vertical through the roof. Only Majestic venting components specifically approved and labelled for this fireplace may be used. Minimum clearances between vent pipes and combustible materials is one (1") inch (25 mm), except where stated otherwise.
  • Page 8: Termination Clearances

    Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Combustible 6"(152mm) Noncombustible 2"(50mm)                     Balcony - Balcony - with no side wall with perpendicular side wall Combustible...
  • Page 9: Assembling Vent Pipes With Crimped Ends

    GENERAL INFORMATION ON ASSEMBLING THE VENT PIPES WITH CRIMPED ENDS Before joining elbows and pipes apply a bead of high temperature sealant to crimped end of 4" and 7" elbow or pipe. (Fig. 9) Join pipes and secure joints with three (3) sheetmetal screws.
  • Page 10: Vertical Sidewall Applications

    Maximum Length 12" (294mm) SCREWS(2) SCREWS(2) ADJUSTABLE ZERO CLEARANCE SLEEVE STEP 3 Measure from fireplace collar to face of outside wall (add 2" for vent pipe overlap. Mark pipes and cut to length. It is very important that the two pipes are flush with the outside wall once the fireplace is in its final location.
  • Page 11 VERTICAL SIDEWALL APPLICATIONS The maximum number of 90 degree elbows per side wall installation is four (4), (includes 7DVRT90 off back of unit) The maximum number of 45 degree elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.
  • Page 12: How To Use The Vent Graph

    HOW TO USE THE VENT GRAPH 1. Determine the height of the centre of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph (Fig. 18), locate the point it intersects with the slanted graph line.
  • Page 13 Maximum Length 12" (294mm) SCREWS(2) SCREWS(2) ADJUSTABLE ZERO CLEARANCE SLEEVE STEP 3 (Fig. 21) Apply a bead of high temperature sealant to the inner and outer flue collars of the fireplace and using appropriate venting component(s) attach to fireplace with three (3) screws.
  • Page 14: Below Grade Installations

    STEP 7 Support the horizontal pipes every 36 inches (914mm) with metal pipe straps. Make sure that the horizontal vent pipe is installed on a level horizontal plane. STEP 8 Recheck the fireplace to make sure that it is levelled, properly positioned, and nailed or screwed to the floor.
  • Page 15: Vertical Through The Roof Applications

    FOUNDATION RECESS WATERTIGHT SEAL AROUND PIPE SHEET METAL SCREWS If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first and then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far protruding wall face (Fig.
  • Page 16: Vertical Through The Roof Installations

    MAX. 8 Ft. (2438mm) MAX. 40 FEET MAX. 8 Ft. (12.2m) (2438mm) MIN. 8 FEET (2.44m) SIDE VIEW Fig. 29 VENT TERMINATION STORM COLLAR ROOF FLASHING ROOF 24" Min. (610mm) ATTIC INSULATION MAX. 40 FEET JOISTS (12.2m) MIN. 8 FEET (2.44m) ATTIC INSULATION SHIELD...
  • Page 17: Dvr Series Crimped End Venting Components

    DVR SERIES CRIMPED VENTING COMPONENTS 7DVRVT - Through the wall Rear Vent Termination Starter Kit -Model 7DVSK - Sidewall Venting Starter Kit - Model 7DVSKV - Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitch for 7DVSKV-B order 7/12 to 12/12 roof pitch for 7DVSKV-F order flat roof Starter Kit - Model 7DVSKS -Snorkel Kit for Below Grade Installation...
  • Page 18: Assembling Twist Lock Vent Pipes

    GENERAL INFORMATION ON ASSEMBLING When using CFM Majestic twist lock pipe it is not neces- sary to use silicone to seal the twist lock joints. The only areas that need silicone are the collars on the fireplace, the telescoping pipe (if used) and the horizontal termina- tion connection (when necessary).
  • Page 19: Rear Wall Installation

    REAR WALL INSTALLATIONS Minimum clearance between vent pipes and combustible materials in one (1") inch (25 mm) on sides and bottom and two (2") inch (50 mm) on top. STEP 1 Locate vent opening on wall. Vent Opening — Combustible Wall (240mm) "...
  • Page 20: Vertical Sidewall Applications

    VERTICAL SIDEWALL INSTALLATIONS Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to. The graph showing the relationship between vertical and horizontal side wall venting will help to determine the various vent lengths allowable.
  • Page 21: How To Use The Vent Graph

    120" 3048mm 90" 2286mm The maximum number of elbow degrees in a system is INSERT . (This does not include transition elbow from rear vent to vertical vent.) Fig. 44 Sample: Total 84" 2134mm 1. Determine the height of the centre of the horizontal elbow=3' 2.
  • Page 22: Vertical Sidewall Installation

    VENT SIDEWALL INSTALLATION *IMPORTANT* Minimum clearance between vent pipes and combustible materials is one (1") inch (25 mm) on bottom, sides and top. Vent Starter Kit 7TDVSK, plus Transition Elbow 7TDVRT90 must be used in Vertical Sidewall installations. pipe must be centred inside the 7" pipe coming off the 7TDVRT90 transition elbow.
  • Page 23: Below Grade Installation

    STEP 5 (Fig. 52) Use the appropriate length of pipe section – telescopic or fixed – and install. The 20" section of pipe which goes through the wall is packaged with the 7TDVSK kit, and can be cut to suit if necessary. Sealing vent pipe and firestop gaps with high...
  • Page 24 DO NOT BACK FILL AROUND SNORKEL. SOIL SHOULD NOT BE LESS THAN 4" BELOW SNORKEL. FOUNDATION RECESS WATERTIGHT SEAL AROUND PIPE SHEET METAL If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first and then secure to snorkel with self drilling #8 x 1/2 sheet metal screws.
  • Page 25: Vertical Through The Roof Applications

    VERTICAL THROUGH THE ROOF INSTALLATION 1. Locate your fireplace. 2. Plumb to centre of the (4") 90 (7TDVRT90) from ceiling above and mark position. 3. Cut opening equal to 9-3/8" x 9-3/8" (240 mm x 240 mm). 4. Proceed to plumb for additional openings through the roof.
  • Page 26: Dvr Series Twist Lock Venting Components

    DVR SERIES TWIST LOCK VENTING COMPONENTS 7DVRVT - Through the wall Rear Vent Termination Starter Kit -Model 7TDVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order flat roof Starter Kit - Model 7TDVSKS -Snorkel Kit for Below Grade Installation...
  • Page 27: Operating Instructions

    OPERATING INSTRUCTIONS GENERAL GLASS INFORMATION Only glass approved for use in Majestic products may be used for replacement. 1 . The use of subsitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. 3.
  • Page 28: Glass Cleaning

    Clean glass after first two weeks of operation. CERAMIC REFRACTORY INSTALLATION DVRS3 (Fig. 66) Rear refractory is already installed from factory. 1 . Unpack ceramic refractory from its carton. HANDLE REFRACTORY CAREFULLY.
  • Page 29: Installation Of Logs

    INSTALLATION OF LOGS Left and right side are defined using the manifold as reference. Facing the manifold,the left side is on your left and the right side is on your right. 1 . Remove left and right side glass. (See "Glass Re- moval"...
  • Page 30: Lighting & Operating Instructions (820 Millivolt Gas Valve)

    LIGHTING AND OPERATING INSTRUCTIONS FOR FIREPLACES EQUIPPED WITH SIT 820 MILLIVOLT GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This fireplace has a pilot which must be lit manually.
  • Page 31: Trouble Shooting (820 Millivolt Gas Valve)

    TROUBLE SHOOTING THE GAS CONTROL SYSTEM GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK START GAS SUPPLY ON LIGHT PILOT WITH PIEZO IGNITION PILOT STAYS ON MAIN BURNER ON SIT 820 NOVA MILLIVOLT VALVE CHECK • SHUTOFF VALVE OPEN • CONFIRM GAS HOOK-UP •...
  • Page 32: Flame Adjustment

    FLAME ADJUSTMENT For fireplaces equipped with Hi/Lo valves, flame adjust- ment is accomplished by rotating the Hi/Lo adjustment knob located near the centre of the gas control. Fig. 71. Turn counterclockwise to increase flame height. FLAME CHARACTERISTICS It is important to periodically perform a visual check of the pilot and the burner flames.
  • Page 33: Replacement Parts Pictorial

    REPLACEMENT PARTS - DVRS3 & DVRSL / DVRSR FOR FIREPLACES EQUIPPED WITH SIT 820 MILLIVOLT GAS VALVE - 33 -...
  • Page 34: Replacement Parts List

    REPLACEMENT PARTS LIST - DVRS3/DVRSL/DVRSR ESCRIPTION Log Set Complete Log - Ember Log Set Log - Ember Log Set Log - Rear Pilot Side Log - Rear Front Side Log - Side Front Log - Side Rear Log - Center Right...
  • Page 35: Options

    FAN KIT - FK24 Fan Specifications: 120 Volt 60 HZ .75 Amp. This fan does not need regular maintenance, however periodic cleaning is required. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month during the operating season.