GLASS CLEANING

It will be necessary to clean the glass periodically.
During start-up condensation, which is normal, forms on
the inside of the glass and causes lint, dust and other
airborne particles cling to the glass surface. Also initial
paint curing may deposit a slight film on the glass. It is
therefore recommended that the glass be cleaned two
or three times with a non-ammonia household cleaner
and warm water (we recommend gas fireplace glass
cleaner). After that the glass should be cleaned two or
three times during each heating season depending on
the circumstances present.
Clean glass after first two weeks of
operation.
INSTALLATION OF LOGS &
BURNER LAVA ROCK MATERIAL
D232
1 . Remove front glass. (See "Glass Removal" section)
2. Remove logs from packaging.
3. Place rear log (KR4) on rear bracket (ensure log is
seated properly, leveled and centered to the unit), so it
will not move from side to side and it is firmly positioned
on the bracket.
4. Slip front ember log (KR1) down in the front deflector.
5. Place front left log (KR2) on top burner, left side. Use
log's bottom holes to locate it into the left bracket log
locator studs.
6. Place front right log (KR3) on top of burner, right side.
Use log's bottom holes to locate it into the right bracket
log locator studs.
7. Place small lava rocks and ember material on top of
burner. (See Fig. 34 for proper location).
8. Place top left log (KR5) onto locator notches. Ensure
log is secure.
9. Place top right log (KR6) onto locator notches. Ensure
log is secure.
Top logs must be placed properly into
notches
D232
KR5
KR2
KR6
KR4
KR3
KR1
Burner Lava Rock Placement
Fig. 34