INSTALLATION - MILLIVOLT
REMOTE WALL MOUNTED SWITCH
A remote wall switch and up to fifteen (15) feet of 18 Ga.
wire may be used with this appliance. Attach the wall
switch in a junction box at the desired location on the
wall. Figure 44. Do not extend beyond the wall switch wire
length provided.
NOTE: Extended lengths of wire may cause the
fireplace not to function properly. Longer length of
wire is permitted if the wire is made out of larger gauge
(diameter) wire. Always check with local code.
PILOT
HI
TH
TP
TH/TP
Figure 44 -
Wiring Diagram for Wall Switch
OPTIONAL FAN/BLOWER SYSTEMS (BLOT)
Installation Instructions
Wiring
1. Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing
the fireplace. Wire with minimum 60° C wire in accor-
dance with prevailing codes.
BLACK
Figure 45 -
Blower Wiring Diagram
20306740
Gray
ON
OFF
FP1980
Dv wiring diagram
Receptacle
Receptacle
BLACK
WHITE
Speed Control
Speed Control
FP2101
DVB Series Direct Vent Gas Fireplace
Do not connect wall switch to (110 V)
circuit.
White
Black
Blue
RS
Black
Blue
Black
2. Remove the external junction box cover by removing
the screw from the left side of the outside firebox wall.
Junction box was installed at the factory.
3. The junction box cover has a factory installed "romex"
style strain relief connector. After connecting the wires,
route the wire leads through this connector. Refer to
the wiring diagram in Figure 45.
Junction
Junction
Box
Box
BLACK
GREEN
BLACK
BLACK
Optional Thermostatic Switch
Optional Thermostatic Switch
OPTIONAL REMOTE
WALL SWITCH
ON
OFF
OPTIONAL REMOTE
WALL SWITCH
ON
OFF
120VAC
120VAC
FP2101a
FP1980
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents