OPTIONAL FAN KIT - FK24
STANDARD WITH RFS42
It will be easier to install the fan before
connecting the gas line to the fireplace.
1. Open front access door panel by pulling forward on
brass lip.
2. Guide the fan through the opening at the back of the
pedestal, with the outlet pointed up and the fan mounting
bracket facing the back of the fireplace. The fan mounts
over two studs which hold the fan just below the firebox
floor. Do not install this fan on the base. Hold the fan
in place with the two nuts provided. (Fig. 7)
3. Locate the fan speed control/junction box on screw
studs provided on base of the fireplace. Tighten with
3/8" nuts provided.
4. Install thermal sensor element on screw studs located
to the right of the gas valve on the burner base.
5. Plug in grounded service cord to a convenient wall
receptacle.
THIS FAN ASSEMBLY COMES COMPLETELY WIRED
TO ELIMINATE THE NEED FOR ELECTRICIANS. THIS
ELECTRICAL DEVICE, WHEN INSTALLED, MUST BE
ELECTRICALLY CONNECTED AND GROUNDED IN
ACCORDANCE WITH LOCAL CODES. IN THE ABSENCE
OF LOCAL CODES, WITH THE CURRENT CSA C22.1
CANADIAN ELECTRICAL CODE.
FOR U.S.A. INSTALLATION: FOLLOW LOCAL CODES
AND THE NATIONAL ELECTRICAL CODE ANSI/NFPA
NO.70-1984.
Should this fan require servicing, the power
supply must be disconnected. For rewiring of
any replacement components see Fig. 6.
A = Speed Control
C
B = Temperature Sensor
B
C = Fan
A
BLACK
WHITE
GROUND
Fig. 6
Stud
Fan is installed at the back
of the pedestal
Thermal sensor
location
Valve
Fan speed control/
Junction box
Fig. 7
TOP VIEW