Gas Line Installation; Remote Switch Installation - Vermont Castings BHDT36 Installation Instructions & Homeowner's Manual

Vermont castings direct vent, top vent installation instructions & homeowner's manual bhdt36
Table of Contents

Advertisement

GAS LINE INSTALLATION

When purging gas line the front glass must
be removed.
The gas pipeline can be brought in through the right side,
left side of the appliance as well as the bottom. Knockouts
are provided at convenient locations to allow for the gas
pipe installation and testing of any gas connection. It is
most convenient to bring the gas line in from the right
side, as this allows fan installation or removal without
disconnecting the gas line.
The gas line connection can be made with
properly tinned 3/8" copper tubing, 3/8"
rigid pipe or an approved flex connector.
Since some municipalities have some
additional local codes, it is always best to
consult your local authority and the CAN/
CGA-B149 (1. or .2) Installation code or for
U.S.A Installations
National Fuel Gas Code, ANSI Z223.1
Always check for gas leaks with a mild
soap and water solution.
open flame for leak testing.
The gas control is equipped with a captured screw type
pressure test point, therefore it is not necessary to provide
a 1/8" test point up stream of the control.
1/2" GAS SUPPLY
1/2" X 3/8" REDUCER
3/8" NIPPLE
3/8" X 3/8" SHUT OFF VALVE
Typical gas supply installation
When using copper or flex connector use only approved
fittings. Always provide a union when using black iron
pipe so that gas line can be easily disconnected for burner
or fan servicing. See Fig. 7. See gas specification for
pressure details and ratings.
The fireplace valve must not be subjected to any test
pressures exceeding 1/2 psi. Isolate or disconnect this or
any other gas appliance control from the gas line when
pressure testing.
consult the current
Do not use an
3/8" NIPPLE
3/8" UNION
3/8" NIPPLE
Fig..7

REMOTE SWITCH INSTALLATION

1. Thread wire through the electrical knockout located on
either side of fireplace.. Do not cut wire or insulation on
metal edges. Ensure that wire is protected. Run the
other end to a conveniently located wall receptacle
box.
2. Attach wire to switch and install switch into receptacle
box. Attach cover plate to switch.
3. Connect wiring to gas valve. (Fig. 8/9)
HONEYWELL VALVE
ALTERNATE SWITCH LOCATION:
Remote switch can be installed on either side of the access
door. Simply mount the switch to the switch bracket
provided. Screw the bracket on either side of the frame,
lining up the screws with the pre-punched holes. (Fig. 10)
DO NOT WIRE MILLIVOLT REMOTE WALL
SWITCH FOR GAS FIREPLACE TO A 120V
POWER SUPPLY.
FOR LIGHTING INSTRUCTIONS PLEASE
TURN TO PAGE 28.
- 7 -
Fig. 8
SIT VALVE
Fig. 9
Fig. 10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents