C.2 Using Device Configuration Utility
NOTE:
This section applies to modules set up in integrated PPP mode which requires data logger
operating system 03.00 or later for the CR1000X, 09.00 or greater for the CR6 series, and 08.00
or later for the CR300 series.
1. Connect the cellular antenna. When using a MIMO antenna with multiple cellular
connections, connect the primary cable to Cellular and the secondary to Diversity. If the
cables are not marked in this way, they can be connected to either antennna port. See
Antenna connections
2. Connect your data logger to the CELL200-series module RS-232 or CS I/O port. See
and connections
3. If not connecting through CS I/O, provide power to the CELL200 series.
4. Connect a USB cable between your data logger and computer.
5. Connect to your data logger by using Device Configuration Utility.
6. When a new CELL200 series OS is available, in the Settings Editor on the Cellular Tab you
will see a field called Cellular OS Update Pending. This field does not appear unless an
update is available. Select Apply Update to begin the process, or Ignore to update at
another time.
7. Apply to save your changes.
8. When new module firmware is available, in the Settings Editor on the Cellular Tab you will
see a field called Cellular Module OTA Update Pending. This field does not appear unless
an update is available. Select Start Update to begin the process, or Ignore to update at
another time.
(p. 28).
(p. 25).
CELL200-Series 4G LTE Cellular Module
Wiring
67