In serial client mode the module will connect to the cellular network and initiate a TCP client
socket connection. When data is sent to the active port (RS-232 or CS I/O) it will be sent out on
the TCP client connection. When data is received on the TCP client socket connection, it is
passed to the active port (RS-232 or CS I/O).
Use this mode when the module is behind a cellular provider firewall and it has a private dynamic
IP address. This mode requires the receiving TCP/IP connection be on a public static IP address,
on the same private cellular network, DNS name or there be a hole in the firewall. For
connections involving firewalls, such as office networks, contact your IT department to ensure all
relevant settings are configured correctly.
When the same server IP and port are used for multiple data logger connections, each data
logger must have a unique PakBus address.
NOTE:
Instructions in this section assume that you have established cellular service and the SIM card
has been installed as described in

6.4.4.1 Configure CELL200 series

To set up the CELL200 series in serial client mode:
1. Connect a USB cable between your module and computer.
2. Connect the cellular antenna. When using a MIMO antenna with multiple cellular
connections, connect the primary cable to Cellular and the secondary to Diversity. If the
cables are not marked in this way, they can be connected to either antennna port. See
Antenna connections
3. Open a web browser and go to: cell.linktodevice.com.