Configure Data Logger - Campbell CELL200 Series Product Manual

4g lte cellular module
Hide thumbs Also See for CELL200 Series:
Table of Contents

Advertisement

2. Connect your data logger RS-232 or CS I/O port to the CELL200-series module RS-232 or CS
I/O port. Ensure the same port is used for each device, for example RS-232 to RS-232. Use
an 18663 cable for RS-232 connection or a SC12 cable for CS I/O connection (either female
connector on the SC12 cable can be used for the CELL220).See
25).
3. If not connecting through CS I/O, provide power to the CELL200 series. The data logger
provides power through the CS I/O port. USB power is not sufficient to power the CELL200
series; 12 V is required.

4.2.2 Configure data logger

1. Connect to your data logger by using Device Configuration Utility.
2. On the PPP tab, set Config/Port Used to CS I/O SDC8 or RS-232, depending on how you
are connected to the data logger.
3. Verify the Modem Dial String setting is blank.
4. If connecting through RS-232, on the Comport Settings tab, set RS232 BaudRate to 115200
Fixed.
5. On the Cellular tab, enter the APN provided by your cellular provider.
Wiring and connections
CELL200-Series 4G LTE Cellular Module
(p.
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cell205Cell210Cell215Cell220Cell225