4.1 Modules using Konect PakBus Router
(private dynamic IP)

4.1.1 Set up hardware

1. Connect the cellular antenna, if it is not already connected. When using a MIMO antenna
with multiple cellular connections, connect the primary cable to Cellular and the secondary
to Diversity. If the cables are not marked in this way, they can be connected to either
antennna port.
2. Connect your data logger RS-232 or CS I/O port to the CELL200-series module RS-232 or CS
I/O port. Ensure the same port is used for each device, for example RS-232 to RS-232. Use
an 18663 cable for RS-232 connection or a SC12 cable for CS I/O connection (either female
connector on the SC12 cable can be used for the CELL220).See
25).
3. If not connecting through CS I/O, provide power to the CELL200 series. The data logger
provides power through the CS I/O port. USB power is not sufficient to power the CELL200
series; 12 V is required.

4.1.2 Configure data logger

1. Connect to your data logger by using Device Configuration Utility.
2. On the Datalogger tab, change the data logger PakBus Address and PakBus/TCP Password
to match the values entered in the Konect PakBus Router setup.
3. On the Network Services tab in the PakBus/TCP Client field, enter the DNS address and
Port number noted during the Konect PakBus Router setup.
4. On the PPP tab, set Config/Port Used to CS I/O SDC8 or RS-232, depending on how you
are connected to the data logger.
5. (Optional) On the PPP tab, set User Name and Password if required by your cellular carrier
(usually outside of the United Sates).
6. Verify the Modem Dial String setting is blank.
7. If connecting through RS-232, on the Comport Settings tab, set RS232 BaudRate to
115200 Fixed.
8. Click Apply to save the changes. Verify the settings in the summary window.
(Recommended) Save a copy of the settings to a file on the computer. Click OK.
9. Shut down Device Configuration Utility and start it again. This will activate the Cellular tab
Wiring and connections