6. (Optional) By default, the CELL200 series will accept incoming communications from any IP
address. This can be a security risk. You may specify up to four IP addresses, with wild cards,
to limit connections to only those trusted sources. Use an asterisk (*) as a wild card. For
example, a setting of 166.22.*.* would allow connections from devices that have IP
addresses starting with 166.22. Both IPv4 and IPv6 addresses are supported.
CAUTION:
Only set a Trusted IP address if you are familiar with their use. Consult your IT
department or Campbell Scientific for assistance.
NOTE:
This setting does not affect outbound connections, only incoming connections.
In the Device Configuration Utility go to the Settings Editor then Network Services. Next to
the Trusted Hosts field, click Edit and Add your trusted IP addresses, one at a time.
7. Click Apply to save the changes.

4.2.3 Set up LoggerNet

The LoggerNet Network Map is configured from the LoggerNet Setup screen.