Permissible Motor Vibration Levels - Siemens SIMOTICS M-1FE1 Configuration Manual

Synchronous built-in motors for sinamics s120
Hide thumbs Also See for SIMOTICS M-1FE1:
Table of Contents

Advertisement

Mechanical properties

3.3 Permissible motor vibration levels

3.3
Permissible motor vibration levels
System vibrations caused by output elements and mounting conditions at the installation
location can affect the vibration values on the motor.
Observe the maximum vibration values on the specified measuring points of the motor.
Table 3- 3
Vibration frequency
< 6.3 Hz
6.3 - 250 Hz
> 250 Hz
Table 3- 4
v
rms
Figure 3-1
Measure the vibration velocity using appropriate measuring equipment.
The vibration acceleration must be evaluated in a frequency band of 10 ... 2000 Hz.
Note
If vibration excitation levels > 2000 Hz (e.g. gear teeth meshing frequencies) can be
expected, the measurement range must be adapted accordingly.
The permitted maximum values remain unchanged.
48
Maximum permitted radial vibration values
Maximum permitted axial vibration values
Vibration velocity
= 4.5 mm/s
Maximum permissible vibration velocity taking into account the vibration
displacement and vibration acceleration
Vibration values
Vibration displacement s ≤ 0.16 mm
Vibration velocity v
≤ 4.5 mm/s
rms
Vibration acceleration a ≤ 10 m/s
Vibration acceleration
a
= 2.25 m/s
peak
SIMOTICS M-1FE1 synchronous built-in motors
Configuration Manual, 09/2019, A5E47872980B AA
2
2