Mounting

7.1

Mechanical mounting

7.1.1

Mounting and removing the rotor (brief form)

7.1.1.1

Tools and resources

You require the following assembly tools and other resources:
● Occupational safety equipment
– Face protection shield
– Protective gloves
– Closed protective clothing for protection against any oil leaks and high or low
● Fixture for checking the radial runout of the spindle shaft
● Depending on the variant used, you require the following mounting tools and
equipment
SIMOTICS M-1FE1 synchronous built-in motors
Configuration Manual, 09/2019, A5E47872980B AA
surface temperatures
WARNING
Risk of explosion when using another coolant for the cold process
Liquid oxygen or liquid air can cause explosions and death or severe injuries.
• Use only liquid nitrogen for the cold process.
Joining with the hot pro-
cess (shrink fit)
Hot-air oven with tem-
perature monitoring -
suitable for temperatures
specified in the "Mount-
ing temperatures" table
Oven volume appropriate
for the rotor type, place-
ment of the oven in the
immediate vicinity of the
workplace
Air-conditioned room or
cold chamber for temper-
ing the spindle shaft and
rotor core
Joining with the cold process
(stretch fit)
Dewar vessel with liquid
nitrogen N2 (-195.8 °C)
For a small workspace:
adequate ventilation
7
Cold-hot process
Hot-air oven with temper-
ature monitoring - suita-
ble for temperatures
specified in the "Mounting
temperatures" table
Oven volume appropriate
for the rotor type, place-
ment of the oven in the
immediate vicinity of the
workplace
Cold chamber for temper-
ing the spindle shaft and
rotor core