Technical data and characteristics

9.3 Characteristics

9.3
Characteristics
9.3.1

Data sheets and characteristics

The data sheets and characteristics for the various motor frame sizes are available in
SIOS under Technical data and characteristics for the SIMOTICS M-1FE1
(https://support.industry.siemens.com/cs/ww/de/view/109771184).
9.3.2

Calculating the acceleration time from the torque/power characteristic

t
ramp-up
J
tot
n
1
n
Bmax
N
max
M
1
P
1
Figure 9-1
Note
The equations provide an approximation and serve as estimate. The precondition is a
constant power range extending from the rated speed up to the maximum operating
speed.
You can calculate the acceleration time using the following program: Tool to calculate
the acceleration time
(https://support.industry.siemens.com/cs/ww/de/view/109771177)
With the 200/250/257 A Motor Modules, the following motors achieve as maximum duty
type S6-40%:
1FE1106-4WN11, 1FE1125-4WN11, 1FE1125-4WP11, 1FE1126-4WN11, 1FE1126-
4WP11, 1FE1126-4WQ11;
The acceleration time does not change appreciably as a result.
132
Ramp-up time in s up to the maximum operating speed
Total moment of inertia of the spindle in kgm²
Rated speed in rpm, e.g. for S6 - 25 %
Maximum operating speed in rpm
Maximum speed in rpm
Acceleration torque in Nm, e.g. for S6 - 25 %
Acceleration power in W, e.g. for S6 - 25 %
Calculating the acceleration time
SIMOTICS M-1FE1 synchronous built-in motors
Configuration Manual, 09/2019, A5E47872980B AA