High-Voltage Test; Voltage Limiting - Siemens SIMOTICS M-1FE1 Configuration Manual

Synchronous built-in motors for sinamics s120
Hide thumbs Also See for SIMOTICS M-1FE1:
Table of Contents

Advertisement

Electrical connection
8.3 System integration
8.3.1.6

High-voltage test

Lethal voltage hazards
A dangerous voltage is present at the motor during a high-voltage test. Death or serious
injury can result when live parts are touched.
• Do not touch any live parts.
• Adhere to the fundamental safety instructions.
NOTICE
Destruction of electronic components and damage to the insulation
A high-voltage test on the motor can damage the insulation of the motor and destroy
electronic components, e.g. temperature sensors.
• Use maximum 80% of the test voltage in accordance with EN 60034-1.
• Prior to the test, short-circuit the cable ends of the temperature sensors.
Before being shipped, the stators of the built-in motors are subject to a high-voltage test
in compliance with EN 60034-1.
However, the Standards Commission recommends that when electrical components
(such as built-in motors) are installed, a new high-voltage test according to EN 60034-1
should be performed after the final assembly has been completed.
8.3.2

Voltage limiting

Note
EMF (Electro Motive Force) > 820 V
In a fault situation, a voltage limitation of the DC-link voltage on the converter is
required. The voltage limit depends on the maximum EMF (induced phase-to-phase
voltage peak > 820 V).
Voltage limiting is required if you operate the motor with a speed n > n
If the power fails (line voltage) at a speed > n
are canceled as a result of the power failure, then the synchronous motor feeds a high
voltage back into the DC link. The voltage protection detects a DC link voltage that is too
high (DC > 820 V) and short-circuits the 3 motor feeder cables. The energy remaining in
the motor is converted into heat as a result of the short-circuit and causes the motor to
quickly brake.
The VPM (Voltage Protection Module) is used as voltage limiter for SINAMICS S120.
114
DANGER
of the motor, or the converter pulses
max inv
SIMOTICS M-1FE1 synchronous built-in motors
Configuration Manual, 09/2019, A5E47872980B AA
.
max inv