Siemens SINAMICS S120 Getting Started page 53

Starter commissioning tool
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Fig. 4-4
You can enter an application monitoring time, which is the time that elapses be-
tween two setpoints before the sign-of-life monitoring function on the drive re-
sponds (fault 1910).
You can use the default monitoring time (e.g. 3000 ms).
3. Since our example concerns commissioning, confirm this dialog box for assum-
ing control priority by choosing OK.
Fig. 4-5
4. To display, amongst other things, the status lamps for the control word bits,
choose Display/hide diagnostics view.
Table 4-1 lists the most important digital input signals of the control word for
sequence control. You need these to set the motor in motion and issue them via
the control panel for the control unit (CU320).
 Siemens AG, 2004. All rights reserved
SINAMICS S120 Getting Started with the STARTER Commissioning Tool – 04.2004 Edition
Using the STARTER Control Panel (Motor Rotates)
Transfer control priority to PC
Status "lamps" for the control word
bits.
Diagnostics view
You can use the default monitoring time
(e.g. 3000 ms).
To continue with commissioning, choose
OK.
Choose Display/hide diagnostics
view.
4-53