Creating the Drive Project OFFLINE
Fig. 3-16
6. You now want to create a drive with a motor module (power section), motor,
and encoder for this example. Confirm the default setting Yes by choosing Con-
tinue >.
Fig. 3-17
7. The drive properties dialog box (see Fig. 3-17) contains general information
about the drive.
8. In the selection field, choose "Operating type".
– Servo: when you are configuring a synchronous motor with servo control
– Vector: when you are configuring an induction motor with vector control
9. Assign a name for the first drive, Drive_1, and enter some general comments.
Choose Continue >.
3-42
SINAMICS_CU320 configuration – Introduction to the drive
Drive properties
SINAMICS S120 Getting Started with the STARTER Commissioning Tool – 04.2004 Edition
Choose Servo or
Vector.