Configuring Local Measuring Inputs - Siemens SIMOTION D410 Series Commissioning Manual

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

SIMOTION Utilities & Applications includes, for example, a tool with the following functions:
● Estimate of the time between initiating a measurement job to the time at which the
● Estimate of the minimum time between 2 measurement jobs
SIMOTION Utilities & Applications is part of the scope of delivery of SIMOTION SCOUT.
Table A- 2
Measuring inputs - Overview of quantity structures and functionality
Functionality/device
Maximum number of
measuring input inputs
Can be configured as a
local measuring input
Can be configured as a
global measuring input
A.3

Configuring local measuring inputs

Properties
Local measuring inputs are always permanently assigned to an axis (drive). They are
configured separately for each drive. The drive and the probe input must always be located
on the same control unit. The measurement results are transferred using the axis message
frame in accordance with the PROFIdrive profile. Message frame 39x does not need to be
configured for local measuring inputs.
The settings for the use of the local measuring inputs must be made in the expert list.
Procedure
To use an I/O terminal on the SIMOTION D410 or SINAMICS Control Unit as a measuring
input, proceed as follows:
1. Double-click on the "Inputs/outputs" entry below the Control Unit in the project navigator.
2. Configure the desired I/O terminal as input in the "Bidirectional digital I/Os" tab. The
SIMOTION D410
Commissioning Manual, 02/2012
measuring input job in the drive acts
Maximum available quantity structure
D410,
D4x5,
CU310,
CU320
CX32
3
6
x
x
x
x
configuration can also be set channel-granular on the p0728 parameter using the expert
list of the control unit.
Configuring drive-related I/Os (without symbolic assignment)
CX32-2
D410-2,
CU310-2
4
8
x
x
x
x
A.3 Configuring local measuring inputs
D4x5-2
TM15
- X122/X132
- X142
- 8
24
- 8
- 8
-
- 0
- 8
x
- 8
TM17 High
Feature
16
-
x
215

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 pnSimotion d410 dp

Table of Contents