4.7.2

Message frame configuration

Prerequisite
You have configured the drive unit.
On the basis of this configuration, one or more of the following actions should be performed:
● The automatic PROFIdrive message frame setting for a drive object should be
● The automatic message frame extension for a drive object should be
● The automatic address adaptation for a drive object should be activated/deactivated
● PROFIdrive message frames should be configured for drive objects
● the addresses should be set up
● Message frames should be extended manually
Procedure
Proceed as follows:
In the project navigator, open the "Communication" > "Message frame configuration" entry
under "SINAMICS_Integrated".
The "SINAMICS Integrated - Message Frame Configuration" dialog box is displayed with the
PROFIdrive PZD message frames tab.
The dialog box lists all the available drive objects. The possible setting options are described
in the following.
Note
When using the symbolic assignment, the default setting does not have to be changed or
configured.
SIMOTION D410
Commissioning Manual, 02/2012
activated/deactivated
activated/deactivated
Commissioning (software)
4.7 Setting up addresses and message frames
115