Automatic Position Controller Setting - Siemens SIMOTION D410 Series Commissioning Manual

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

Commissioning (software)
4.14 Optimizing the drive and controller
7. Disable the drive by clicking the "Drive OFF" button.
8. Click "Give up control priority" to give up control priority of the PG/PC.
9. Save the online parameters.
You can now transfer the parameters that you have automatically set to the project.
Backing up parameters
Proceed as follows to back up the parameters:
1. In the project navigator, select the SINAMICS device with the drive for which you want to
2. Select "Target device" > "Copy RAM to ROM" in the context menu.
3. Select "Target device" > "Load to PG" from the context menu.
If necessary, the automatic controller settings can be verified with the measuring functions.
4.14.3

Automatic position controller setting

Introduction
In the "Automatic Controller Setting" screen form, you can select the drive unit and the drive
for which you want to perform automatic DSC position controller setting. The steps required
for this calculation can be performed via this screen form. The calculated Kv value is
displayed and can then be accepted online in the configuration data of the axis that is
assigned to the drive.
Prerequisites
In addition to the general prerequisites for automatic controller setting, the following
boundary conditions apply for setting the position controller:
● DSC is required for position controller setting.
Note
Activate the project setting "Use symbolic assignment" and select the Standard/Automatic
option for the axis-drive communication when configuring the drives. You automatically
use DSC for the servo drives with these settings.
● The speed controller must have already been configured (e.g. using automatic speed
● One axis must be connected to the SINAMICS drive (servo).
● An online connection to the SIMOTION device must be established to transfer the results
● The balancing filter is not changed.
140
perform automatic setting.
controller setting).
of automatic position controller setting.
SIMOTION D410
Commissioning Manual, 02/2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 pnSimotion d410 dp