Commissioning (software)
4.6 Creating and testing an axis
Axis test
1. Open the "AXES" folder in the Project Navigator and click the "Control panel" entry below
Figure 4-23
Axis control panel
2. To display the control range and axis diagnostics, click the "Show/hide control range" and
3. Click "Assume control priority".
Note
In order to move the axis from the PG/PC, you must assume control priority. However, by
pressing the SPACER bar, you can stop the axis at any time.
112
the axis (for example, Axis_1).
The axis control panel is displayed.
"Show/hide diagnostics area" buttons.
If the CPU is in RUN mode, confirm the notice that appears with "Yes" to set the
controller to STOPU mode.
SIMOTION D410
Commissioning Manual, 02/2012