Editing Sinamics Components - Siemens SIMOTION D410 Series Commissioning Manual

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

Result
The DRIVE-CLiQ components loaded to the user project by means of automatic
configuration are displayed in the project navigator.
Figure 4-13
You must then
● If required, reconfigure SINAMICS components (e.g. components without a DRIVE-CLiQ
● Assign the "TO axis" to "Drive".
See also
Editing SINAMICS components (Page 89)
4.3.4

Editing SINAMICS components

Prerequisites
● You have uploaded all connected DRIVE-CLiQ components to the user project.
● You shut down the connection to the target system (offline mode).
SIMOTION D410
Commissioning Manual, 02/2012
Project Navigator with the downloaded DRIVE-CLiQ components
interface, such as an encoder connected to the onboard encoder interface).
Commissioning (software)
4.3 Performing an online configuration
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 pnSimotion d410 dp

Table of Contents