Siemens SIMOTION D410 Series Commissioning Manual page 108

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

Commissioning (software)
4.6 Creating and testing an axis
● Create drive
● Set up addresses
The address list in the "All addresses" view provides an overview of the assignments to all
interfaces of the TO axis. From this view, the assignments can also be changed via the
interconnection dialog box (
Note
The methods of the drive and axis configuration, previously available in SCOUT versions
< V4.2, are still available. Symbolic assignment must be deactivated in such cases.
108
From the assignment dialog box, a new drive can be created on an existing drive unit
(e.g. SINAMICS Integrated) and assigned to the axis. This allows the axis, including the
drive, to be created in one operation. It is not necessary to configure a drive before
creating an axis.
If "Use symbolic assignment" is deactivated, the addresses must be set up manually. This
corresponds to the previous method of configuring the drive and axis, which was
available in SCOUT versions < V4.2.
This method is necessary e.g. for drive units which do not support symbolic assignment
(such as SINAMICS S120 with FW version < 2.6.2, MASTERDRIVES, SIMODRIVE, etc.)
button).
SIMOTION D410
Commissioning Manual, 02/2012