Tone Test; Send Tone Test (-S) - 3Com CommWorks 5210 User Manual

Ip telephony manager
Table of Contents

Advertisement

114 A
: C
L
I
PPENDIX
OMMAND
INE
NTERFACE

Tone Test

This section describes how to send and receive a tone test.

Send Tone Test (-S)

The following command causes the modem to send a tone of the specified
frequency, duration, and amplitude.
tcmtone -S[-t][-s num][-p num]
[freq[hz][level[db]]]target
Where:
-S
Initiates send tone test.
-t
Leave in test mode after exiting program.
-s
Specifies duration number in seconds. Default = 10.
-p
Specifies time between polls num in seconds. Default = 1.
Freq
Specifies frequency. Must be one of the following: 404, 1004, 2804. Default =
404. If specified, frequency must appear after all other flags and before level
and target.
Hz
Optional (ignored). "hz" or "Hz" can be included for clarity.
Level
Specifies amplitude (integer) in dBm. Valid range = 0 to -43. Default = 0. If
specified, frequency must immediately precede level.
Db
Optional (ignored). "db" or dBm" can be included for clarity.