Input Failure On An Rps And Ac-Powered Switch; Hot-Swappable Power Module Failure - H3C S5560S-SI Installation Manual

Hide thumbs Also See for S5560S-SI:
Table of Contents

Advertisement

2.
Verify that the RPS is operating correctly.
3.
Verify that the operating temperature of the switch is in the acceptable range, and the power
module has good ventilation. Over-temperature can cause the power module to stop working
and enter protection state.
4.
If the issue persists, contact H3C Support.

Input failure on an RPS and AC-powered switch

Symptom 1
The system status LED on the RPS and AC-powered switch is off.
Solution
To resolve the issue:
1.
Verify that the AC power cord is securely connected to the switch, and the AC-input power
receptacle on the switch and the connected AC power outlet are in good condition.
2.
Verify that the AC power source is operating correctly.
3.
Verify that the switch is securely connected to the RPS.
4.
Verify that the RPS is operating correctly.
5.
Verify that the operating temperature of the switch is in the acceptable range, and the power
module has good ventilation. Over-temperature can cause the power module to stop working
and enter protection state.
6.
If the issue persists, contact H3C Support.
Symptom 2
The system status LED on the RPS and AC-powered switch is on but the RPS status LED is steady
yellow.
Solution
To resolve the issue:
1.
Verify that the AC power cord is securely connected to the switch, and the AC-input power
receptacle on the switch and the connected AC power outlet are in good condition.
2.
Verify that the AC power source is operating correctly.
3.
Verify that the operating temperature of the switch is in the acceptable range.
4.
If the issue persists, contact H3C Support.
Symptom 3
The system status LED on the RPS and AC-powered switch is on but the RPS status LED is off.
Solution
To resolve the issue:
1.
Verify that the switch is securely connected to the RPS.
2.
Verify that the RPS is operating correctly.
3.
Verify that the operating temperature of the switch is in the acceptable range.
4.
If the issue persists, contact H3C Support.

Hot-swappable power module failure

The S5560S-28F-SI, S5560S-28DP-SI, and S5130S-28F-SI switches use hot-swappable power
modules. You can determine the power module operating status by examining the power module
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents