Fan Tray Failure; Configuration Terminal Issues; No Display On The Configuration Terminal - H3C S5560S-SI Installation Manual

Hide thumbs Also See for S5560S-SI:
Table of Contents

Advertisement

LEDs PWR1 and PWR2 on the switch front panel. For descriptions about the PWR1 and PWR2
LEDs, see
"Appendix C Ports and
Symptom
A PWR LED indicates a power module failure.
Solution
To resolve the issue:
1.
Verify that the power module model is as required.
2.
Verify that the power module is installed correctly in the switch.
3.
Verify that the switch is operating in the acceptable temperature range.
4.
If the issue persists, contact H3C Support.
To replace a hot swappable power module, see

Fan tray failure

Symptom
The system status LED on the switch indicates a fan tray failure.
Solution
When a fan tray issue occurs, contact H3C Support.

Configuration terminal issues

No display on the configuration terminal

Symptom
The configuration terminal does not have display when the switch is powered on.
Solution
To resolve the issue:
1.
Verify that the power system is operating correctly.
2.
Verify that the switch is operating correctly.
3.
Verify that the console cable has been connected correctly.
4.
Verify that the following settings are configured for the terminal:
Baud rate—9600.
Data bits—8.
Parity—None.
Stop bits—1.
Flow control—None.
5.
Verify that the console cable is not faulty.
6.
If the issue persists, contact H3C Support.
LEDs."
"Installing and removing a power
38
module."