Maintenance And Troubleshooting; Fixed Power Module Failure; Ac Input Failure; Dc Input Failure - H3C S5560X-30C-EI Installation Manual

Hide thumbs Also See for S5560X-30C-EI:
Table of Contents

Advertisement

5

Maintenance and troubleshooting

Fixed power module failure

The S5560X-30F-EIF, S5560X-34S-EI, and S5560X-54S-EI switches use fixed power modules and
support AC power input, DC power input, and concurrent AC and DC power inputs.
S5560X-34S-EI and S5560X-54S-EI switches—To identify a fixed power module failure,
examine the system status LED and the RPS status LED on the switch.
S5560X-30F-EIF switch—To identify a fixed power module failure, examine the system status
LED, AC power input status LED, and DC power input status LED.
Table5-1 Description of LEDs for fixed power modules
LED
System status LED
RPS status LED
AC input power
status LED
DC input power
status LED

AC input failure

Symptom
The switch uses only AC power input. The system status LED is off.
Solution
To resolve the issue:
1.
Verify that the AC power cord connects the switch to an AC power source correctly, and the AC
power receptacle on the switch and the AC power outlet are in good condition.
2.
Verify that the AC power source is operating correctly.
3.
Verify that the ambient temperature of the switch is in the acceptable range and ensure good
ventilation for the power module. Overtemperature can cause the power module to stop
working and enter the protection state.
4.
If the issue persists, contact H3C Support.

DC input failure

Symptom
The switch uses only DC power input. The system status LED is off.
Mark
Status
SYS
Off
Steady green
RPS
Steady yellow
Off
Steady green
AC PWR
Off
Steady green
DC PWR
Off
5-50
Description
The switch is powered off.
Both the DC input and the AC input are normal.
Normal DC input, no or abnormal AC input.
No or abnormal DC input.
Normal AC input.
No or abnormal AC input.
Normal DC input.
No or abnormal DC input.

Advertisement

Table of Contents
loading

Table of Contents