Maintenance and troubleshooting

Fixed power module failure

The switches (except the S5560S-28F-SI, S5560S-28DP-SI, and S5130S-28F-SI models) use fixed
power modules. The S5130S-28S-HPWR-LI, S5130S-52S-PWR-LI, S5120V2-28P-HPWR-LI,
S5120V2-52P-PWR-LI, S5024PV3-EI-HPWR, S5048PV3-EI-PWR, and S3100V3-28TP-PWR-SI
switches support AC power input, RPS power input, and concurrent AC and RPS DC inputs. The
other switch models support only AC power input.
To identify a power failure on the switch, examine the system status LED and the RPS status LED on
the switch.
Table 10 Description for the power failure indication LEDs
LED
System status LED
RPS status LED
(available only on the
S5130S-28S-HPWR-LI,
S5130S-52S-PWR-LI,
S5120V2-28P-HPWR-LI,
S5120V2-52P-PWR-LI,
S5048PV3-EI-PWR, and
S3100V3-28TP-PWR-SI
switches)

Input failure on an AC-powered switch

Symptom
The system status LED on an AC-powered switch is off.
Solution
To resolve the issue:
1.
Verify that the AC power cord is securely connected to the switch, and the AC-input power
receptacle on the switch and the connected AC power outlet are in good condition.
2.
Verify that the AC power source is operating correctly.
3.
Verify that the operating temperature of the switch is in the acceptable range, and the power
module has good ventilation. Over-temperature can cause the power module to stop working
and enter protection state.
4.
If the issue persists, contact H3C Support.

Input failure on an RPS-powered switch

Symptom
The system status LED or RPS status LED on the RPS-powered switch is off
Solution
To resolve the issue:
1.
Verify that the switch is securely connected to the RPS.
Mark
Status
SYS
Off
Steady green
Steady yellow
RPS
Off
36
Description
The switch is powered off.
Both the RPS input and the AC input are normal.
Normal RPS input, no or abnormal AC input.
No or abnormal DC input.